2.13. TYPE TEST
2.13.1. EMC – Emissions
Emission: Reference standard EN 61000-6-3 (2001) + EN 61000-6-3/A11 (2004)
Test specifications
EN 55022
EN 55022
EN 55014-1
EN 61000-3-2
EN 61000-3-3
2.13.2. EMC – Immunity
Immunity: Reference standard EN 61000-6-2 (2005)
Test specifications
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
(+)
Apparatus does not contain devices susceptible to magnetic fields
The compatibility test results according to the 89/336 EEC and 2004/108 EC Directives and subsequent amendments.
2.13.3. Climatic
Reference standard DNV No. 2.4 – 2006
Test specifications
Class: C (-25°C / +55°C)
Standard IEC 60068-2-2
Class: C (-25°C / +55°C)
Standard IEC 60068-2-2
Class: C (-25°C / +55°C / 100% R.H.)
Standard IEC 60068-2-30
2.13.4. Vibrazioni
Reference standard DNV No. 2.4 – 2006
Test specifications
Class: B
Standard IEC 60068-2-6
2.13.5. Shock & Bump
Test specifications
IEC 60255-21-2
IEC 60068-2-27
963857137_G
Environmental Phenomena
Conducted disturbance
Radiated disturbance
Discontinuous disturbance voltage
Harmonic current emissions
Voltage fluctuations and flicker
Environmental Phenomena
Electrostatic discharge
Radiated electromagnetic field
Electrical fast transients
Surge
Injected currents
Power frequency magnetic field
Dips/short interruptions
Environmental Phenomena
Dry Heat
Cold
Damp Heat
Environmental Phenomena
Vibration
Environmental Phenomena
Shock response test (Class 2 – 10g, 11ms, 3*3)
Shock withstand test (Class 2 – 30g, 11ms, 3*3)
Bump test (Class 2 – 20g, 16ms, 1000*3)
Shock response test (+/-5g, 10ms, 10*3)
MEC-100
Result
Complies
Complies
Complies
Complies
Complies
Result
Complies
Complies
Complies
Complies
Complies
N.A. (+)
Complies
Result
Complies
Complies
Complies
Result
Complies
Result
Complies
Complies
11