See the manual for local or remote communication accessories to obtain more
information about local communication via Ethernet and/or Wi-Fi and remote
communication with the INGECON SUN EMS Board.
Consult the accessories manual for communication via RS-485 for further
information on the RS-485 connection.
For more information about installing the INGECON SUN EMS Board in the
inverter please see the installation manual for the unit in question.

3.2 Settings

3.2.1 Factory settings

For Ethernet communication, the EMS energy manager is configured to obtain
its IP address dynamically via DHCP.
For Wi-Fi communication, by default the EMS energy manager acts as a Wi-Fi
access point. Once it is powered up, it emits a SoftAP network with an SSID.
AAX2026IQM05_B.docx
·
The SSID is an Ingeteam_xxMxxxxxxAxx_MMMM type, where
xxMxxxxxxAxx coincides with the Device ID of the EMS energy manager
and MMMM with the last four digits of the MAC address of the same.
·
When the EMS energy manager acts as an access point and creates a
Wi-Fi network, its IP address is:
- 169.254.1.1 para versiones de FW AAX1055_P y posteriores.
- 192.168.10.3 para versiones de FW anteriores.
Configuration manual