b. Connection of an electric catch or lock
Directly connect the electric catch or lock to the
NB: this function is only operational if communication is established with the roadside panel.
Important :
The keeper or electric lock that you are going to install must always be itted with a mechanical memory like all
EXTEL references. For the wiring report to the label stuck on the rear of the roadside panel.
c. Connection of a gate motor
Connect directly the gate motor to the terminals
a current-free "dry" contact to connect to the "push button" control of your automatic gate opener.
NB: this function is only operational if communication is established with the roadside panel.
d. Connecting an optional extra WEPACB 247 BIS indoor station (
1. Connect the wires as shown in the connection plan (fig.6)
2. To connect the indoor station to the extra WEPACB 247 BIS indoor station, 6 wires are needed for all the
functions. If you use a shielded or screened cable (providing a better communication quality), connect the shield
or the screen to the terminal "3" of each unit.
•Terminal «0» of the response unit on terminal «0» of the extra indoor station
•Terminal «1» of the response unit on terminal «1» of the extra indoor station
•Terminal «2» of the response unit on terminal «2» of the extra indoor station
•Terminal «3» of the response unit on terminal «3» of the extra indoor station
•Terminal «4» of the response unit on terminal «4» of the extra indoor station
•Terminal «5» of the response unit on terminal «5» of the extra indoor station
Cable calibre: from 0-20 metres : 6 x 6/10th wires
Caution :
In any case, do not double the wires to increase size
6

USING

a. Using the interphone
• A call on the roadside panel will trigger an audible signal on the answering unit. You have 30 sec. to answer. Press
the key "parole"
to communicate with your visitor.
One press of the
• The keeper or electric lock is controlled using the
• The mechanism is controlled using the
button*.
• The "Monitoring" function (for listening to the street) is controlled using the
* in "communication" mode only
b. Indoor unit settings
4 adjustments can be accessed on the side of the indoor unit:
• Cut ringing (0). The
• Melody select (1-Ding dong, 2- S.A.C or 0-mute) (8).
• Melody volume control
4GB
CFI EXTEL WEPA 245 BIS SER.R1 & WEPA 246 BIS SER.R1 - 11/2010 - V1
(fig. 6)
button is enough to establish communication with the street plate.
*.
(fig.2)
indicator then blinks on the front of the indoor unit.(8).
(9).
(fig. 6)
"+,-" (ignore the polarity).
at the back of the roadside panel. The roadside panel supplies
* .
fig.6)
button.