Assembly
Power Supply
The measuring tool can be used either with commercially avail-
able batteries/rechargeable batteries, which are inserted in
battery compartment 16, or with the CST/berger battery pack
18.
Operation with Batteries/Rechargeable Batteries
Using alkali-manganese or rechargeable batteries is recom-
mended for operation of the measuring tool.
– To insert the batteries/rechargeable batteries, loosen nut 19
and remove the battery compartment 16.
When inserting the batteries/rechargeable batteries, pay atten-
tion to the correct polarity according to the representation on
the inside of the battery compartment.
Always replace all batteries/rechargeable batteries at the same
time. Do not use different brands or types of batteries/re-
chargeable batteries together.
– Mount the battery compartment 16 again. Pay attention that
the nose of the battery compartment engages in the corre-
sponding recess in the housing (see illustration on the graph-
ic pages). Firmly tighten the battery compartment with nut
19.
Remove the batteries/rechargeable batteries from the
measuring tool when not using it for longer periods.
When storing for longer periods, the batteries/rechargeable
batteries can corrode and self-discharge.
Operation with Battery Pack
Charge the battery pack 18 before using for the first time. The
battery pack can only be charged with the battery charger 31 in-
tended for it.
– Insert the charge plug 32 of the battery charger into the
socket connector 17 of the battery pack. Connect the bat-
tery charger to the mains supply. Charging the empty battery
pack takes approx. 14 h.
A battery that is new or has not been used for a longer period
does not develop its full capacity until after approx. 5 charg-
ing/discharging cycles.
Do not charge the battery pack 18 each time after using, other-
wise its capacity will be reduced. Charge the battery pack only
when the charge-control indicator 6 flashes or lights up contin-
uously.
A considerably reduced operating period after charging indi-
cates that the battery pack is used up and must be replaced.
– To replace the battery pack 18, loosen nut 19 and remove
the battery pack 18.
– Mount a new battery pack 18. Pay attention that the nose of
the battery pack engages in the corresponding recess in the
housing (see illustration on the graphic pages). Firmly tight-
en the battery pack with nut 19.
Remove the battery pack from the measuring tool when
not using it for longer periods. When storing for longer pe-
riods, the rechargeable batteries can corrode and self-dis-
charge.
800.544.2843
2 609 141 178 • 2.4.14
www.calcert.com
15
10
20
5
25
0
30
Charge-control Indicator
When the charge-control indicator 6 flashes red for the first
time, the measuring tool can still be operated for approx. 2 h.
When using commercially available batteries/rechargeable bat-
teries, the remaining operating duration may differ.
When the charge-control indicator 6 lights up red continuously,
measurements are no longer possible. The measuring tool
switches off automatically after 1 minute.
Operation
Initial Operation
Protect the measuring tool against moisture and direct
sun light.
Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. As an example, do not
leave it in vehicles for a long time. In case of large variations
in temperature, allow the measuring tool to adjust to the am-
bient temperature before putting it into operation. In case of
extreme temperatures or variations in temperature, the ac-
curacy of the measuring tool can be impaired.
Avoid heavy impact to or falling down of the measuring
tool. After severe exterior effects to the measuring tool, it is
recommended to carry out an accuracy check (see "Accura-
cy Check of the Measuring Tool", page 32) each time before
continuing to work.
Setting Up the Measuring Tool
Horizontal position
(RL25H/RL25HV)
Vertical position
– Position the measuring tool on a stable surface in the hori-
zontal or vertical position, mount it to a tripod or to the wall
mount 28 with alignment unit.
Due to the high levelling accuracy, the measuring tool reacts
sensitively to ground vibrations and position changes. There-
fore, pay attention that the position of the measuring tool is sta-
ble in order to avoid operational interruptions due to re-level-
ling.
Switching On and Off
To save energy, only switch the measuring tool on when you are
using it.
– To switch on the measuring tool, press the On/Off button 2.
This is confirmed by brief flashing of all indicators.
RL25H: Immediately after switching on, the measuring tool
sends out the variable laser beam 14.
RL25HV: Immediately after switching on, the measuring tool
sends out the variable laser beam 14 and the plumb beam
15.
Do not point the laser beam at persons or animals and do
not look into the laser beam yourself, not even from a
large distance.
(RL25HV)
English | 29