Assembly
Installing the lifting column at the interfaces > Installing the internal profile - Multilift I/II

5.4 Installing the lifting column at the interfaces

5.4.1 Installing the internal profile - Multilift I/II

Positioning the lifting column
Fastening the lifting column
Fig. 28: Connection points
I/II
104
Personal:
Schutzausrüstung:
Prerequisite:
n
The screwing surface on the connecting construction has been
prepared for fastening the lifting column.
1.
Place the internal profile of the lifting column on the screwing
surface on the connecting construction, and position it.
2.
Insert 4 screws into the drilled holes (Fig. 28/1) on the con-
necting construction and lifting column.
- Multilift
3.
Tighten the screws alternating between them diagonally.
Screw size
M8
ð The Multilift II lifting column has been fitted to the con-
Lifting column Multilift I/Multilift II
RK Rose+Krieger GmbH recommends that the lifting
column be fastened to the supporting/contact surface
on the motor side.
n
Assembly staff
n
Protective clothing
n
Protective gloves
n
Safety shoes
The screwing surface on the connecting con-
struction must rest flat on the lifting column.
The supporting surface of the lifting column must
rest fully on a metal plate of at least 5 mm in
thickness.
Strength
8.8
The minimum screw depth for initial installation is
20 mm, and 40 mm for repeated installation.
Use all the connection points of the Multilift for
the connecting constructions and options mod-
ules.
necting construction.
Tightening torque [Nm]
15