8.4.2 Maximum torque values - Multilift II
Views
Multilift II Standard/ESD/clean
Multilift II impact
Multilift II telescope/telescope
ESD
8.5 Rating plate
Fig. 39: Rating plate
20.02.2019
Maximum torque values with load via the ...
... long side
n
200 Nm (dynamic)
n
300 Nm (static)
n
200 Nm (dynamic)
n
300 Nm (static)
n
200 Nm (dynamic)
n
300 Nm (static)
The rating plate (Fig. 39) is located on the motor housing.
1
Sales number
2
Customer item number
3
Serial number
4
Voltage, max. current consumption, travel speed
5
Max. tensile/compressive load
6
Duty cycle
7
Caution! Danger!
8
Do not dispose of with household waste!
9
CE marking
10 Only use in closed rooms!
11 Observe the instructions!
12 Year of manufacture
13 Type designation
Lifting column Multilift I/Multilift II
Technical data
... short side
n
130 Nm (dynamic)
n
200 Nm (static)
n
130 Nm (dynamic)
n
200 Nm (static)
n
100 Nm (dynamic)
n
200 Nm (static)
Rating plate
121