Technical data
Torque values > Maximum torque values - Multilift I
Supporting construction
Fig. 38: Supporting construction
8.4 Torque values
8.4.1 Maximum torque values - Multilift I
Views
Multilift I
with extending inner profile
with internal carriage
120
1
Supporting construction
2
Supporting force
The supporting construction (Fig. 38/1) must withstand a sup-
porting force (Fig. 38/2) of 6000 N in maximum conditions
(impulse).
A safety factor is not included.
Maximum torque values with load via the ...
... long side
n
150 Nm (dynamic)
n
300 Nm (static)
n
75 Nm (dynamic)
n
150 Nm (static)
Lifting column Multilift I/Multilift II
... short side
n
100 Nm (dynamic)
n
200 Nm (static)
n
50 Nm (dynamic)
n
100 Nm (static)
20.02.2019