799 GPT Titrino
Wrong sample. For SET, KFT or DOC with preset titration direction
the first measured value lies behind the endpoint.
Exit: The error message disappears on next startup.
No EP set for SET, STAT.
Exit: The error message disappears on next startup.
Silo empty and it has been started with open silo or empty silo has
been opened.
Exit: Send a silo entry.
Silo full.
Exit: Send new command.
No method. A method, which is required from the silo memory or in TIP, does
not exist.
Exit: The error message disappears on next startup.
Check temp.sensor in MEAS T or with activated temperature monitoring.
Exit: Correct error or &m $S.
Same buffer in CAL. Measured value of the second buffer differs less than 6
mV from the measured value of the first buffer.
Exit: Correct error or &m $S.
XXX Bytes are missing so that the method, the silo line could not be stored or
not enough RAM for running TIP.
Exit: Send new command.
Rate missing for calculation.
Exit: The error message disappears on next start or on recalculation.
Number of rates does not agree with the set windows or the mean rate C80
could not be calculated.
Exit: The error message disappears on next start or on recalculation.
Fix volume missing for calculation.
Exit: The error message disappears on next startup or on recalculation.
No new silo result (C24 or C25).
Exit: The error message disappears on next start or on recalculation.
No sequence defined in TIP.
Exit. The error message disappears on next start.
A second TIP has been called up in TIP.
Exit: The error message disappears on next start.
No new temporary variable.
Exit: The error message disappears on next start.
Measurement range of the secondary measured value (temperature)
exceeded. The primary measured value (pH, U, Ipol, Upol) can also be
unstable.
Exit: Rectify error or &m $S.
No ramp end set in DOC.
Exit: The error message disappears on next start or &m $S.
Save lines is "OFF" although a submethod of TIP includes an assignment to
C24 or C25.
Exit: The error message disappears on next start. Attention: The data of this
sample will not be stored.
Rate too high in DOS. No dispensing possible with the Exchange Unit currently
mounted.
Exit: The error message disappears on next start or &m $S.
Fix time missing for calculation.
Exit: The error message disappears on next start or on recalculation.