Simer 2925B -01 Serie Manual Del Usuario página 3

Sistema de bomba de lavadero
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
13. Make certain the power source conforms to the
requirements of your equipment.
14. Protect the electrical cord from sharp objects, hot sur-
faces, oil, and chemicals. Avoid kinking the cord.
Replace or repair damaged or worn cords immediately.
15. Do not touch an operating motor. Motors can oper-
ate at high temperatures.
Risk of electric shock. Shock can burn
or kill. If your basement has water or moisture on
floor, do not walk on wet area until all power has
been turned off. If shut-off box is in basement, call
electric company or hydro authority to shut-off ser-
vice to house, or call your local fire department for
instructions. Failure to follow this warning can result
in fatal electrical shock.
Risk of electric shock. Shock can burn
or kill. Do not handle pump or pump motor with
wet hands or when standing on wet or damp surface,
or in water. Always disconnect the pump and float
switch from the electrical power source before doing
any maintenance.
16. Pump water only with this pump.
INSTALLATION
(See Figure 1, Page 4)
The laundry pump system should be located at the low-
est place possible relative to the area to be drained.
1. Install the inlet pipe in the opening as shown. Use
Teflon
tape to seal threads. See Figure 2 for typical
TM
installation arrangements.
2. Install the discharge plumbing. When using a rigid
pipe, use plastic pipe. Wrap the thread with Teflon
tape. Screw the pipe into the check valve coupling
hand tight +1 to 1-1/2 turns. Make sure the longer
Check Valve Installation.
For parts or assistance, call Simer Customer Service at
3. A short length of rubber hose (1-7/8" (47.6 mm) I.D.,
4. Install the in-line check valve on the pump outlet to
5. Push the vent pipe into the black vent grommet in
6. Power Supply: The pump is designed for 115V., 60
7. If the pump discharge line is exposed to outside sub-
TM
8. Install easy disconnecting fittings on the inlet pipe and
9. After the piping and check valve have been installed,
1 1/4" Coupling
10. Check operation by filling the basin with water and
Check Valve
TM
Pump Outlet
side of the coupling points downward to cover the
check valve.
NOTICE: The check valve MUST be installed with
the word TOP facing up.
NOTICE: Do not use ordinary pipe joint compound
on plastic pipe. Pipe joint compound can attack
plastics.
or a quick-disconnect should be attached to the dis-
charge line. This will help when removing the pump
for maintenance. A rubber hose may also dampen
pump noise and vibration.
prevent backward flow through the pump when the
pump shuts off.
the basin cover. The pipe should not extend into the
basin. Connect the pipe to the sewer vent system.
Hz., operation and requires a minimum 15 amp
individual branch circuit. Both the pump and the
switch are supplied with 3-wire cord sets with
grounding-type plugs. Insert the float switch piggy-
back plug directly into the outlet and the pump plug
into the opposite end of the switch plug.
Risk of electric shock. Shock can burn
or kill. The pump should always be electrically
grounded to a suitable electrical ground such as a
grounded water pipe or a properly grounded metallic
raceway, or ground wire system. Do not cut off
round ground pin.
freezing atmosphere, the portion of line exposed
must be installed so any water remaining in pipe will
drain to the outfall by gravity. Failure to do this can
cause water trapped in discharge line to freeze
which could result in damage to the pump.
on the discharge pipe just below the check valve.
the unit is ready for operation.
observing the pump's operation through one com-
plete cycle.
Risk of Flooding. Flooding may cause
personal injury or property damage. Failure to make
this operational check may lead to improper opera-
tion, premature failure, and flooding.
E.I. DuPont de Nemours and Company Corporation.
1-800-468-7867 / 1-800-546-7867
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

2925b

Tabla de contenido