2 - BUZZER
At the end of each tightening, a sound informs the operator of the tightening result:
•
1 beep -> tightening correct
•
2 beeps -> tightening not correct or faulty operation
3 - DISPLAY
At the end of each tightening, the tightening result and the torque value are displayed, alternatively. In case of faulty operations,
the corresponding error code will also be displayed.
3.1 - Tightening results
Tightening correct
Torque low
For further information, see "ERROR TABLE", page 19.
3.2 - Faulty operations
Faulty operations are coded so that the operator can efficiently locate the default. To know the signification of each code, see
"ERROR TABLE", page 19.
EAP-TFlex tools
TIGHTENING RESULTS
Torque high
Torque > disassembly limit
Part no
6159932890
Issue no
02
Language English
Date
01/2010
166
Page
17 /
Overspeed