Part no
6159932890
Issue no
02
Language English
Date
01/2010
166
Page
6 /
The EAP-TFlex tool is an electric fastening tool directly supplied by mains. It is fitted with a torque transducer for high-precision
torque control. The main regulation parameter is the torque, which can be changed using the display and the 3 programming keys.
Tool type
A=angle-head
Motor type
Maximum torque in Nm
(30 Nm or 65 Nm)
There are several options:
EAP2-65-TF*
EAP2-30-TF*
TF for TFlex; * = 1 for 115 VAC, 2 for 230 VAC
1 - MAINS SUPPLY
There are 2 types of tools:
•
one tool which works with 230 VAC mains voltage, ± 8%, 50/60Hz
•
one tool which works with 115 VAC mains voltage, ± 8%, 50/60Hz
Although the peak power can reach 2 kW during the final speed phase, it is recommended to adjust the power circuits according
to the maximum average power.
The average power input depends on the tool type, the assembly type and the tightening rate. However, for heat dissipation
reasons, the maximum average power should not exceed 0.3 kW.
2 - FEATURES
Protection level
EN 60745
Noise level
EN 60745
Vibration level
Declaration of noise and vibration emission
All values are current as of the date of this publication. For the latest information please visit cp.com.
These declared values were obtained by laboratory type testing in accordance with the stated standards and are suitable for
comparison with the declared values of other tools tested in accordance with the same standards. These declared values are not
adequate for use in risk assessments and values measured in individual work places may be higher. The actual exposure values
and risk of harm experienced by an individual user are unique and depend upon the way the user works, the workpiece and the
workstation design, as well upon the exposure time and the physical condition of the user.
We, Chicago Pneumatic, cannot be held liable for the consequences of using the declared values, instead of values reflecting the
actual exposure, in an individual risk assessment in a work place situation over which we have no control.
This tool may cause hand-arm vibration syndrome if its use is not adequately managed. An EU guide to managing hand-arm
vibration can be found at http://www.humanvibration.com/EU/VIBGUIDE.htm
CHAPTER 2 - DESCRIPTION AND OPERATION
EAP 2 - 65 - TF 2
screwing with a torque value from 15 to 65 Nm ±10%
screwing with a torque value from 6 to 30 Nm ±10%
IP40
< 70 dBA
< 2.5 m/s²
EAP-TFlex tools
Tool option
TF=TFlex
Voltage
1=115 VAC
2=230 VAC