Design and Function
3.3.1
Webtec CAN / External CAN
You can use the CAN X and CAN Y ports to connect the device
via CAN BUS lines and additional Y-junctions to up to 24 Webtec
sensors (max. 24 channels ) with automatic sensor detection
(Webtec CAN).
Fig. 4
Connection port, CAN X / CAN Y
PIN Designation
1
Shielding
2
+Ub (+24 V
3
GND
4
CAN High
5
CAN Low
INFORMATION
The CAN X and CAN Y ports are not galvanically separated. A galvan-
ic separation is only provided in the optional CAN Input Module.
22
4
3
1
2
)
DC
5