Trigger Logic - WEBTEC HPM7000 Manual De Instrucciones

Ocultar thumbs Ver también para HPM7000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.5.5

Trigger Logic

The Trigger logic measuring method starts recording of the measured
values after one or two defined triggers are triggered.
Recording is stopped after one or two defined triggers are triggered.
INFORMATION
Please note that you must define the start/stop conditions in order to
be able to use this measuring method.
Select between the following combinations as the start conditions for the
measurement:
■ Condition A
■ Conditions A and B
■ Conditions A or B
Select between the following combinations as the stop conditions for the
measurement:
■ Condition C
■ Conditions C and D
■ Condition C or D
The following triggers are available for the start conditions:
Trigger A
Level
Window
Time
External
Keystroke
Channel
warning value
Channel alarm
value
Trigger B
Trigger C
Level
Level
Window
Window
Time
External
External
Duration
Channel
warning value
Channel alarm
value
Operation
Trigger D
Level
Window
External