STORAGE & MAINTENANCE
WINTERIZING:
For storage and transportation purposes in subfreezing ambient
temperatures, it will be necessary to winterize this unit. This unit must be
protected to the lowest incurred temperature for the following reasons:
1. If any part of the pumping system becomes frozen, excessive pressure
may build up in the unit which could cause the unit to burst resulting in
possible serious injury to the operator or bystanders.
2. The pumping system in this unit may be permanently damaged if frozen.
FREEZE DAMAGE IS NOT COVERED BY WARRANTY.
If you must store your unit in an area where the temperature may fall
below 32°F, you can protect your unit by following the procedure outlined
below.
1. Gather the following items:
a. Two 5 gallon containers.
b. One gallon of antifreeze.
antifreeze.)
c. Water supply.
2. Procedure:
a. Mix antifreeze and water in a container that can be used for pouring
the solution into the float tank.
NOTE: Proper winterizing is based on the recommended manufacturer's
instructions listed on the "Protection Chart" shown on the back label
of most antifreeze containers.
b. To start winterizing, unit must be run according to the "Start-Up/Cold
Water Operation" listed on pg. 14.
c. After running, shut off the unit and water supply.
d. Relieve system pressure by pointing the trigger gun in a safe
direction and squeezing the trigger until water flow ceases to exit
the nozzle.
e. Lock the trigger gun in the OFF position and remove the nozzle.
f.
Remove lid from the float tank.
g. Start the unit and squeeze the trigger gun until the float tank is almost
empty. Release trigger.
h. Carefully pour antifreeze solution into float tank.
i.
Point the trigger gun into the empty container. Trigger the gun until
the antifreeze begins to exit the trigger gun.
j.
Stop the unit.
k. Disconnect the hose and trigger gun from the unit and drain any
excess antifreeze back into the 5 gallon container.
l.
Drain hose, trigger gun and lance assembly and store with the unit
in a safe non-freezing area.
m. Store antifreeze solution for next use or dispose of according to state
EPA laws.
OPTIONAL PROCEDURE:
a. Shut off the unit and water supply.
b. Relieve system pressure by pointing the trigger gun in a safe
direction and squeezing the trigger until water flow ceases to exit
the nozzle.
c. Disconnect and drain the hose, trigger gun and lance assembly.
d. Remove the coil drain plug from the heat exchanger inlet.
e. Start the unit and allow it to run until all the water exits the unit. Once
the water has stopped flowing from the unit, turn unit off.
NOTE: When using this procedure, use caution as ice chips can form from
drops of water which could cause the unit to burst if starting before
completely thawed.
HSD-SERIES Operator's Manual
(Use an environmentally safe
WARNING
RISK OF UNIT BURSTING.
DO NOT STORE / OPER-
ATE UNIT IN A FREEZING
ENVIRONMENT!