CLEANING THE OUTER HOUSING AND INTAKE GRILLE
If dust has accumulated on the unit, use a soft, dry dusting towel to wipe it off. If grease or
other harder to remove substances is on the unit, use a wrung-out cloth dampened with
warm, soapy water. Use a soft brush to clean off the grille.

CLEANING THE FILTER

For energy efficient operation, your filter should be cleaned every three months. Units in
dusty environments may require more frequent filter cleaning.
The front filter cover rests on a bottom hinge and swings down. Open by using
pulls on either side of the cover.
Remove the filter by gently tugging on it.
Use a vacuum cleaner or run cold water onto the filter to clean it. If the filter is par-
ticularly dirty (such as grease buildup), wash and gently scrub the filter in a bath of
warm soapy water. Let the filter completely dry in a shady place; exposing the filter
to direct sunlight can cause deformation.
After the filter is clean and completely dry, re-insert the filter by pressing firmly
without forcing.
Note: To avoid deformation and fire risk, never dry the filter with a heat source, such as a
hair dryer, fireplace, or heater.

TROUBLESHOOTING

PROBLEM / POSSIBLE CAUSES
The air conditioner does not function at all
• Is the power cable properly inserted into a functioning, grounded outlet?
• Is there a power failure such as a blown fuse or tripped circuit breaker?
• Is the timer set to "TIMER ON" mode? Disable the timer to immediately start op-
erations.
• Is the internal collection tank or partition drain full/blocked and the FULL light
illuminated? Empty the tank.
• Is the ambient temperature lower than 61°F (16°C)? A safety device prevents the
unit from cooling the room to even lower temperatures.
Heating or cooling is insufficient
• Is the room temperature set properly?
• Is the air filter dirty?
• Are doors or windows open?
• Is the room directly exposed to sunlight or are other heat sources in the room?
• Are there a large number of people in the room?
The air conditioner does not restart immediately after turning it off.
• The unit can not be restarted for 3 minutes to allow the condenser to cool and
avoid risk of fire. Wait a few minutes before restarting the unit.