3.1
Unscrew and Discard the Five Screws and Five
Shipping Retainers from the Motor Hub (Figure 1) .
3.2
Mount Flanges to Fan Blades using Three M5 x 6mm
Washer Head Blade Screws (supplied in parts bag)
(Figure 2) .
3.3
NOTE: Take care not to scratch fan housing when
installing blades.
Loosely attach one Blade/Flange Assembly to the Motor
Hub by securing the Two M6 x 14mm Captive Pan
Head Screws . Make sure the Screws are NOT tightened
(Figure 3) .
Repeat this procedure for other Four Blade Assemblies .
WARNING
!
To reduce the risk of personal injury, do not bend the
flange when installing the blades, balancing the blades
or cleaning the fan. Do not insert foreign objects in
between rotating fan blades.
3. Ceiling Fan Assembly
REMOVE AND DISCARD THE FIVE
SHIPPING RETAINERS AND SCREWS
FROM THE MOTOR HUB
Figure 1
M5 x 6mm WASHER
HEAD BLADE SCREW
(3 per blade/flange)
FLANGES (5)
Figure 2
BLADE/FLANGE
ASSEMBLY
M6 x 14mm CAPTIVE
PAN HEAD SCREW
(2 per blade/flange assembly)
Figure 3
Please contact 1-800-777-4440 for further assistance
5
FAN BLADES (5)
luminancebrands.com
U.L. Model No.: CF542 & CF552