Abicor Binzel iSTM Instructivo De Servicio página 33

Soporte poro robot
Ocultar thumbs Ver también para iSTM:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

iSTM
6.4 Attaching the ABIROB
®
W torch neck
1
ABIROB
Positioning pin
2
Attaching the ABIROB
Fig. 8
1 Equip the ABIROB
gas nozzle.
2 Insert ABIROB
iSTM (4).
3 Tighten the set screws (5) with a hexagon wrench (2). Tightening torque
M= 2.5 Nm.
4 Close lock ring (3) by rotating it to the left.
®
W torch neck
1
iSTM
3
Connection module
4
®
W torch neck
1 Equip the ABIROB
gas nozzle.
2 Introduce positioning pin (2) into marked bore.
®
The ABIROB
W torch neck (1) can only be fastened in this position.
3 Tighten ABIROB
®
The ABIROB
W torch neck (1) is now attached.
NOTE
• After using the torch for several days, it may happen that it cannot be
disconnected by hand. To do this, a suitable wrench is available. Do not
use pliers to disconnect the torch.
®
A torch neck (1) with a tip adaptor, contact tip and
®
A torch neck (1) via the guide grooves until the stop in the
2
5
®
W torch neck (1) with a tip adaptor, contact tip and
®
W torch neck (1) with retaining nut (5) on the iSTM (3).
6 Putting into operation
3
4
Retaining nut
5
EN - 13