Troubleshooting - Abicor Binzel iSTM Instructivo De Servicio

Soporte poro robot
Ocultar thumbs Ver también para iSTM:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10 Troubleshooting

10 Troubleshooting
Problem
Problem when mounting the
hose assembly into the iSTM
Hose assembly makes ripples
in the robot axis
Troubleshooting
Tab. 10
11 Dismounting
EN - 20
NOTE
• Some problems are listed below, with descriptions of possible causes
and solutions. If the measures described below are not successful, please
consult your dealer or the manufacturer.
• Please also consult the operating instructions for the welding
components, such as power supply, air pressure line.
Cause
• No grease on the O-rings of the
adapter
• The hose assembly adapter is
not correctly inserted into the
module
• Hose assembly too long
Dismounting may only be carried out by specialized personnel. Please make
sure that the shutdown procedures are strictly observed, before the dismounting
work begins. Ensure this also for the components integrated into the welding
system.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Cut off the compressed air supply.
• Switch off the entire welding system.
• Pull the mains plug.
NOTE
• Observe the information given in section 8 Putting out of operation on
page EN-15.
1 Disconnect the hose assembly from the wire feeder.
Solution
• Grease the O-rings
(included in the scope of
delivery)
• Use the pull-in tool
• Align the guide groove
• Change the feeding system
positioning, if possible
iSTM

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Abirob a360Abirob a500Abirob 350gcAbirob w500 ts

Tabla de contenido