Items Included; Skills Taught; Unpack; Airway Management - Laerdal ALS Simulator Instrucciones De Utilizacion

Ocultar thumbs Ver también para ALS Simulator:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13

Items Included:

ALS Simulator
(1) Adult, Full-body Simulator
(1) Articulating IV Training Arm
(1) Blood Pressure Training Arm
(1) Manikin Lubricant
(1) Interchangeable Pupil Set
(6) Neck Skin Collars
(1) Cricothyroid Membrane Tape Roll
(1) Set of Replacement Pneumothorax Bladders
(2) Mid-Clavicular Bladders
(2) Mid Axillary Bladders
(6) Chest Drain Modules
(1) Blood Pressure Cuff
(1) Air Pump
(1) Set of Defibrillation Posts
(1) Carry Case
(1) Jacket
(1) Pants
(1) Directions for Use
(1) Laerdal Global Warranty Booklet

Skills Taught:

Airway Management Skills
• Assessment of Respirations
• Obstructed airway
• Tongue Edema
• Right Lung Blockage
• Left Lung Blockage
• Both Lung Blockage
• Endotracheal intubation
• Nasotracheal intubation
• Digital intubation
• Oropharyngeal airway insertion
• Nasopharyngeal airway insertion
• Bag Valve Mask
• Retrograde intubation
• Lightwand intubation
• Laryngeal Mask Airway insertion
• Laryngeal Tube Insertion
• Combitube insertion
• Trans-Tracheal Jet Ventilation
• Surgical cricothyrotomy
• Needle cricothyrotomy
• Suctioning techniques
• Stomach auscultation to verify proper airway positioning
• Head Tilt/Chin Lift
• Modified Jaw thrust
• Ventilations
Drug Administration
• IV insertion, infusion and bolus into peripheral veins of forearm, antecubital
fossa and dorsum of the hand
• Subcutaneous and intramuscular injections

Tension Pneumothorax Decompression

• Bilateral mid-clavicular sites
• Mid-axillary site (Right)
Chest Tube Insertion
• Mid-axillary site (Left)
Laerdal
Cardiac Related Skills
• 3 – 4 lead ECG with over 1100 rhythm variations available for interpretation.
• Pacing with variable threshold, with or without capture
• Defibrillation capabilities (25 -360 joules)
• Programmable scenario base algorithms for instructor control
• Closed chest compressions
Circulatory Skills
• Bilateral carotid pulse
• Measurement of Noninvasive Blood Pressure
- Brachial and radial pulses
- Auscultation or palpation of noninvasive blood pressure measurement
- Values to be set for systolic, diastolic pressures, heart rate, auscultatory gap
and volume
Sounds and Speech
Refer to SimPad DFU
Logging and Scenario Functions
Refer to SimPad DFU

Unpack:

The ALS Simulator is packaged without the legs attached . Remove the upper
body and legs from the packaging and attach the legs to the torso .
To attach Right Leg (with enclosed air tank):
1 . Remove bladder reservoir from pelvis .
2 . Remove blank genitalia module from pelvis .
3. Carefully slide the tubing and wiring exiting the fixed bolt from the upper
thigh of the right leg through the connector hole and into internal cavity of
pelvic area . (Photo 1)
4 . Continue to advance the bolt and wiring though the connector hole until the
thigh is flush with the pelvis of the manikin.
5 . From inside pelvic area, slip the longer air connection tube through the
provided thumb nut, then slip the shorter electronic wire through the
thumb nut .
6 . Connect the wire and cable inside the pelvis .
7 . Tighten the thumb nut until desired articulation is achieved .
8 . Replace bladder reservoir in torso .
9 . Replace blank genitalia module in pelvic region of torso .
2
Photo 1
ALS Simulator

Publicidad

Tabla de contenido
loading