Static and dynamic loads on the floor or
foundation are shown in the table below. This
table can be used as a reference when
designing floors and foundations.
Static floor load, lbs (kN)
2
Static pressure, lbs/ft
(kN/m
Dynamic floor load, lbs (kN)
2
Dynamic pressure, lbs/ft
(kN/m
Dynamic load frequency, Hz
1
Maximum vertical load, lbs (kN)
2
Minimum vertical load, lbs (kN)
Base moment, lb/ft (kN/m)
1
Acting in the downward direction against the floor.
2
Acting in the upward direction away from the floor.
F232084
UWPV Pocket Hardmount Floor Load Data
Design Series
U1-U5
1271 (5.64)
U6 and greater
1272 (5.66)
2
U1-U5
169 (8.08)
)
U6 and greater
169 (8.08)
U1-U5
1647 (7.3)
U6 and greater
1648 (7.33)
2
U1-U5
219 (10.5)
)
U6 and greater
219 (10.5)
U1-U5
U6 and greater
U1-U5
2712 (12.0)
U6 and greater
2719 (12.1)
U1-U5
582 (2.59)
U6 and greater
576 (2.56)
U1-U5
4250 (5.35)
U6 and greater
4249 (5.8)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
35
60
1677 (7.45)
2506 (11.2)
1677 (7.45)
2292 (10.2)
188 (9.00)
187 (8.94)
184 (8.79)
2824 (12.6)
3683 (16.38)
2824 (12.6)
3679 (16.36)
317 (15.2)
295 (14.2)
317 (15.2)
295 (14.2)
13.3
12
15
13.6
4184 (18.6)
5493 (24.43)
4168 (18.5)
5482 (24.38)
1464 (6.50)
1873 (8.3)
1450 (6.45)
1852 (8.24)
8894 (11.2)
11853 (16.1)
8895 (12.1)
11951 (16.2)
Installation
80
100
2741 (12.2)
2490 (11.1)
200 (9.6)
219 (10.5)
199 (9.6)
3681 (16.37)
3690 (16.41)
294 (14.1)
295 (14.2)
11.2
10
12.8
12.8
5551 (24.69)
5561 (24.73)
1811 (8.1)
1794 (8.0)
11849 (16.1)
11984 (16.3)
125
3571 (15.9)
3283 (14.6)
223 (10.7)
205 (9.8)
5016 (22.31)
5011 (22.29)
313 (15.1)
312 (15)
9.7
9.7
7561 (33.63)
7559 (33.62)
2471 (11)
2434 (10.8)
16702 (22.7)
16606 (22.5)
19