Figure 12
F232084
Tubing from
Pump
Seal Nut
Tubing
Ring
Base
Lid
Nut
P041IE3A
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
Connecting External Liquid Supplies
to the Washer-Extractor
1. Remove plugs from base. See Figure 12.
Plugs are assembled inside the tubing ring.
2. Install strain reliefs, included in the seal
nut.
3. Insert tubes through base. Do not remove
cups. Tube should extend into the plastic
cup, with the exception of the softener
tube, which should be routed to the outside
of the cup.
4. Tighten the seal nut to prevent tubing from
escaping the assembly.
Do not attempt to make chemical injection
electrical connections to points other than
those provided specifically for that purpose by
the factory.
Chemical Injection Supply System
Number of dry supply compartments
Number of liquid supply connections
Liquid supply connection size, in (mm)
5
5
5/8 (15.9)