ENGLISH
HI-MIG 300K-P 400V 3F
TECHNICAL DESCRIPTION
COD. 6902100050
FUNCTION STORING AND LOADING WELDING PARAME-
TERS (JOB MODE)
Function active for all welding modes
This function allows you to store and load at any time all the settings made on the gen-
erator. It is possible to save 99 welding parameters (settings).
STORING WELDING SETTINGS
1) Press simultaneously for 1 second the buttons bb (ref.9 page 9) and PG (ref.11 page
9); you will hear a double sound of the buzzer and the letters PrG will blink on the left-
hand display (ref.5 page 9).
2) By means of the encoder V/SET (ref.8 page 9), select the number of the program in
which you want to save the welding parameters.
3) Press and hold down for more than 2 seconds the SELECT MODE button (ref.29
page 9); you will hear 4 sounds of the buzzer and the letters Sto will blink on the left-
hand display (ref.5 page 9). At this point the program has been saved and you can con-
tinue using the machine.
LOADING STORED WELDING PROGRAMS
1) Press simultaneously for 1 second the buttons bb (ref.9 page 9) and PG (ref.11 page
9); you will hear a double sound of the buzzer and the letters PrG will blink on the left-
hand display (ref.5 page 9).
2) By means of the encoder V/SET (ref.8 page 9), select the number of the program
that you want to load.
3) Press and hold down for more than 2 seconds the SET button (ref.10 page 9); you
will hear 4 sounds of the buzzer and the letters ReC will blink on the left-hand display
(ref.5 page 9).
At this point the program has been loaded and you can continue using the machine.
ATTENTION : you can store a welding program on any program number already mem-
orised. The data of the deleted program will be definitively lost.
STEL s.r.l. – Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 444 639525 (central.) – +39 444 639682 (comm.)
FAX +39 444 639641 – E-mail: stel @ stelgroup.it
http: www.stelgroup.it