TECHNICAL DESCRIPTION
COD. 6902100050
CONNECTION
- Before making the electrical connections between the current generator and the line
switch, ensure that the switch is turned off .
- The distribution panel must comply with the regulations in force in the country of use
(
).
- The mains system must be of the industrial type.
- Provide a special socket which can receive the leads of the power cable (200A: 4mm
section ; 350A:6mm section ).
- For longer connecting cables, increase the lead section as required.
- Upstream, the mains socket must have a suitable switch provided with delayed fuses.
MODEL
VOLTAGE/PHASES
DELAYED FUSE
400V 3 phases without
HI-MIG 300K-P
50 A
neutral

3.4 - EARTHING

- To ensure user protection the welding machine must absolutely be correctly connect-
ed to the earth system (INTERNATIONAL SAFETY REGULATIONS).
- It is indispensable to provide good earthing by means of the yellow-green lead in the
power cable, in order to avoid discharges due to accidental contacts with earthed ob-
jects.
- The chassis (which is conductive) is electrically connected with the earth lead; if the
equipment is not suitably connected to earth it may cause electric shocks which are
dangerous for the user.