Applicable documents
Applicable documents
DE
EN
Description
External mains power supply unit
FR
Push-on connector
IT
ES
WiFi antenna
Current sensors
PT
NL
SV
FI
DA
Wall-mounted distribution box
NO
EL
Basic safety principles
CZ
DANGER
HU
Injuries due to electric shock and/or burns, possibly
PL
resulting in death, are possible.
e During all work, make sure at all times that power
HR
to the system is switched off and secured so it
SR
cannot inadvertently be switched on.
e Do not open the housing of the energy manager
SK
under any circumstances.
SL
ET
LT
LV
RO
BG
MK
18
Type
STEP-PS/ 1AC/24DC/0.75, article number 2868635
2x1754571, 1x1790108, 1x1790111, 3x1790124,
1x1939439
HiRO H50284 wireless 802.11n 2.4GHz WiFi gain 2dBi OMNI
EChun ECS1050-L40P (50 A input; 33.3 mA output)
EChun ECS16100-L40M (100A input; 33.3 mA output)
EChun ECS24200-L40G (200A input; 33.3 mA output)
EChun ECS36400-L40R (400A input; 33.3 mA output)
EChun ECS36600-L40N (600A input; 33.3 mA output)
TT 100-SD (LEM, 100 A input; 33.33 mA output)
733414911
Qualification of personnel
The electrical installation may only be performed by
Danger to life due to
persons with the relevant knowledge of electrical/
electrical voltage!
electronic equipment (electrician). These persons
must provide proof that they have the specialist
knowledge required to install electrical systems in
the form of an examination certificate.
Improper installation can endanger your own life and
that of others.
Requirements for the electrician performing the
installation:
– Ability to evaluate test results
– Knowledge of IP ratings and their use
– Knowledge about fitting of electrical installation
material
– Knowledge of the applicable electrical/electronic
and national regulations
– Knowledge of fire safety measures and general
and specific safety and accident prevention
regulations
Note
Info
www.phoenixcontact.com
www.phoenixcontact.com
www.hiroinc.com
All Echun models have
www.echun-elc.com
a 33 mA output
www.lem.com
www.spelsberg.com
– Ability to select suitable tools, testers and, if
necessary, personal protective equipment, as
well as the electrical installation materials for
ensuring tripping conditions
– Knowledge of the type of electricity network (TN,
IT and TT System) and the resulting connection
requirements (protective earthing, earthing
without a PE conductor, additional measures
necessary)
Notes on installation
Electrical installation must be performed in such a
way that:
– Protection from contact in accordance with
locally applicable regulations is ensured at all
times for the entire electrical installation.
– Locally applicable fire safety regulations are
complied with at all times.