3.2
Functional description
3.2.1 Tool AT2000 CPK
12
11
10
9
8
1 Release button for left service cover
2 Actuator bandoleer cutter
3 Socket for connection to power pack
4 Enter button for conirming a selection
5 Select and reset button for selecting a menu
6 LED status indicator
7 Start trigger
8 Box for waste material
9 Display with touch-sensitive controls
10 Front cap with level sensor, upper and lower jaws
11 Catch
12 Drum
13 Cable tie bandoleer
The AT2000 CPK is an electrically powered system for
bundling electrical wires, for example, and for securing
parts of various kinds with T18RA cable ties, 100 mm ×
2.5 mm × 1 mm (L × W × T).
Force and quality of the binding can be software-
controlled or set by means of the display on the device.
The items to be bundled have to be positioned between
the jaws and against the front cap. The device then
closes the tie as soon as the trigger is pressed.
If a fault occurs, messages appear on the display to step
the user through the recommended fault-diagnosis
routine.
Process data of various kinds are collected during use.
These data can be analysed by PC software and used to
document process capability, for example. In addition,
the operator is notiied if the tension force exceeds the
preset.
Operating Instructions • AT2000 CPK • 02-2017 • v02 • 106-29004
13
7
6
5
4
3.2.2 Power pack CPK
6
1
2
5
3
1 Main switch
2 LED indicator
P o w e r
:
Green: Power pack ON
3 LED indicator
S i g n a l
:
Green: AT2000 CPK Connected and ready,
Red: Fault
Yellow: Binding cycle active
Blue: Navigation in main menu, binding not possible
4 LED indicator
D a t a
:
Green: PC connected; AT2000 CPK connected; USB stick found; USB stick can be
removed,
Red/green lashing: Data are being written to USB stick
5 USB port for exporting process data to USB memory stick
6 Socket for connection to AT2000 CPK
In: Last Tie
3
1 Socket for foot pedal
2 USB port for connection to PC
3 Socket for power supply
In automatic systems, the AT2000 CPK can be integrated
with the power pack with control box (106-00110) via a
serial interface.
Design and function
Power pack CPK
Data
Signal
Power
4
3
2
Out: Error
Out: Busy
Serial port
max. 250V~
1
1
2
10