9.4.2 Changing back-up battery
DANGER
A hazardous electrical current lows though the body
in direct or indirect contact with electrically live parts.
Electric shock, burns or death can result.
f Work on the electrical supply and on parts that are live
when the device is in operation should always be carried
out by a person duly authorised to work on low-voltage
electrical equipment.
f Use only OEM fuses of the speciied amperage.
f Have faulty electrical components replaced immediately.
f Always disconnect the plug from the power-supply outlet
before starting maintenance work and troubleshooting.
f Check the electrical equipment of the device at regular
intervals. Have defects such as loose connections or
scorched wiring repaired immediately.
f Switch the power pack OFF.
f Disconnect the power cord from the power-supply
outlet.
1
P o
w e
r p
a c
k C
P K
2
D a
ta
S ig
n a
l
P o
w e
r
f Remove housing screws
f Remove housing
from the power pack.
2
f Change back-up battery
For details of battery type, à "Power pack CPK" on
page 33
f Reit the housing and secure it by tightening housing
screws
.
1
f Set the date and time, à "Date / time" on page 14.
Operating Instructions • AT2000 CPK • 02-2017 • v02 • 106-29004
.
1
.
3
10
Maintenance
10.1 Important notes
Regular servicing is essential in order to ensure that the
device remains in safe working order, à "Maintenance
schedule" on page 30.
CAUTION
Crush hazard when jaws close.
f Do not insert ingers between upper and lower jaws and
do not keep your inger on the trigger.
f Always keep the power pack switched OFF while
maintenance is in progress.
CAUTION
Crush hazard due to moving/rotating parts when service
covers are open.
f Do not insert ingers underneath the drum and do not
keep your inger on the trigger.
f Always keep the power pack switched OFF while
maintenance is in progress.
10.2 Accessories and extras
Accessories and extras can be ordered directly from your
national HellermannTyton representative, à separate
spare parts list.
Name
1
Power pack CPK
CPK Operating Instructions on CD
CPK safety warnings
Bench mount kit CPK
Overhead suspension CPK
10.3 Servicing by manufacturer
It is advisable to have the AT2000 CPK serviced by
HellermannTyton once a year or after every approx. 1
million bindings. This will allow the AT2000 CPK to be
3
checked and updated to the latest modiication status.
Service contact addresses for all countries are posted on
the website:
www.HellermannTyton.com
Maintenance
Article number
106-00100
106-29004
106-29003
106-00040
106-00050
29