Combustion Chamber; Compatible Burners; Water Head Losses - Sime Estelle B4 INOX ErP Instrucciones De Instalación Y Mantenimiento

Ocultar thumbs Ver también para Estelle B4 INOX ErP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
1.5
COMBUSTION
CHAMBER (fig. 3)
The combustion chamber is of the
straight flow type and complies with
standard EN 303-3 appendix E.
The dimensions are shown in fig. 3.
L
mm
B4 INOX ErP
405
B5 INOX ErP
505
1.6
COMPATIBLE BURNERS
(
EN 267)
In general, the oil burner that is
compatible with the boiler should
use spray of the semi solid type.
Section 1.6.1 shows the matching ta-
ble of the burners together with the
boilers have been tested with.
1.6.2
Burners assembly
(fig. 3/a)
The boiler door details is shown in
figure 3/a for burner mounting.
The burners must be regulated such
that the CO
value is that indicated in
2
point 1.3, with a tolerance of ± 5%.
1.7
WATER HEAD LOSSES (fig. 4)
220
200
180
160
140
120
100
80
60
40
20
0
44
Volumen
3
dm
24,0
30,5
1.6.1 "SIME" burners
B4 INOX ErP
B5 INOX ErP
500
1000
1500
270
Code
Model
Nozzle Atomising
ø
8099170 FUEL 25 ErP
0,55
8099171 FUEL 35 ErP
0,65
2000
2500
3000
Water flow (l/h)
Portata acqua (l/h)
L
Pump
Class
Adsorbed power
angle
pressure bar
NOx
consumption W
60°S
12,5
1
80°S
13
1
NOTE: Water head
losses obtained with
∆t 10°C.
Fig. 3
175
195
Fig. 3/a
Fig. 4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Estelle b5 inox erp