cable, and requires a a single-phase
power supply of 230V - 50Hz through
the main switch protected by fuses.
The room thermostat (required for
enhanced room temperature con-
trol) should be installed as shown in
KEY
TS
Safety stat
EI
Summer/Winter switch
TA
Room stat
TB
Tank stat
TC
Boiler stat
TL
Limit stat
IG
Main switch
PB
D.H.W. pump
PI
C.H. pump
B
Permanent Feeding Burner SIME (optional)
B1
Permanent Feeding Burner (not supplied)
48
fig. 5/a. Connect the burner and sys-
tem circulation pump power cables
supplied.
NO T E: Device must be connected to
an efficient earthing system.
B2
Direct Feeding Burner (not supplied)
R/R2 Relay
SA
Power on light
SPA Water pressure gauge triggered light
PA
Water switch
OP
Timer programmer (optional)
TM
Minimum stat
NOTE: When connecting the room stat (TA) remove
the bridge between terminals 20-21.
When connecting the Timer Programmer (OP) remo-
ve the bridge between terminals 30-31.
SI M E de c li n es all responsibility for
injury caused to persons due to
failure to earth the boiler.
Always turn off the power supply
before doing any work on the elec-
trical panel.
Fig. 5/a