2. Connect the Breakout cable's trigger and strobe wires to an appropriate
device (for example, a trigger sensor or strobe light).
Note:
I/O wiring or adjustments to I/O devices should be performed
l
when the camera is not receiving power.
The Ethernet cable should be unplugged or the PoE source
l
powered down before making adjustments to the
connections at the far end of the Breakout cable.
Unused wires can be clipped short or tied back using a tie
l
made of non-conductive material.
3. Connect one end of the Ethernet cable to the camera's ENET connector. If
installing the In-Sight 8405 camera and using a compatible horizontal
screw-locking Ethernet cable, use a screw driver to tighten the connector
screws until snug, to secure it to the camera. The screws must be tight to
ensure a reliable connection.
CAUTION:
The Ethernet cable must be shielded. For the In-Sight 8405
l
camera, Cognex strongly recommends Cat 6 or Cat 7
Ethernet cables with S/STP shielding.
The Ethernet cable shield must be grounded at the far end.
l
The vision controller's CAM ports provide Power over
l
Ethernet (PoE) to supported Cognex devices; connecting
other PoE devices to these ports could damage the vision
controller or the PoE device.