Vision Controller Specifications
Specifications
Current
Voltage
Power Consumption
Operating Temperature
Storage Temperature
Humidity
Altitude
Protection
Shock (Storage and Shipment)
Vibration (Storage and Shipment)
1
To ensure sufficient ventilation, the vision controller must be mounted with sufficient clearance. If mounting to the
bottom surface, 50mm of clearance is required above and on both sides of the vision controller. If mounting to the
back surface or using the accessory wall mounting bracket or DIN rail mounting bracket, 24.5mm of clearance is
required above, below and on both sides of the vision controller. If an adjacent device also produces heat, additional
space or cooling is required if air space around the vision controller exceeds 45°C (113°F).
3.5A (maximum)
24VDC ±10%
84W (maximum)
1
0°C to 45°C (32°F to 113°F)
-30°C to 80°C (-22°F to 176°F)
10% - 85%, non-condensing (Operating and Storage)
2,000m (6565ft)
IP30
30 G, per IEC 60068-2-7EA.
2 G, 2 hrs/axis (10-500 Hz) per IEC 60068-2-6, FC.
Vision Controller