5.1.3 Motor cable

The motor cable is fitted to the motor via a cable entry. The
enclosure class is IP68. The length of the cable is 10 m.
Nameplate, motor
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Fig. 4
Nameplate, motor
Pos.
Description
1
Ex mark
Type designation
2
(not filled out, see name plate lifting station)
3
Product number
4
Production code (year/week)
Maximum head
5
(not filled out, see name plate lifting station)
6
Number of phases
7
Rated input power
8
Rated speed
Rated voltage, Δ
9
10
Rated voltage, Y
11
Frequency
12
Weight without cable
13
Operation mode
14
CE mark
15
Explosion protection
16
Enclosure class to IEC
Maximum installation depth (not filled out, see
17
nameplate lifting station)
Maximum flow rate
18
(not filled out, see name plate lifting station)
19
Maximum liquid temperature
20
Output power
21
Power factor
Rated current, Δ
22
23
Rated current, Y
24
Starting capacitor
25
Operating capacitor
26
Insulation class
27
Country of production
5.1.4 Grinder system
The grinder system consists of two parts, a stationary grinder ring
and a rotating grinder head. See fig. 5.
The grinder ring is secured to the pump housing by means of a
bayonet socket and fixed in the right position with a screw. The
grinder head is secured to the shaft by means of the screw that
keeps the impeller in position. To adjust or replace grinder
15
system, see service instructions.
16
17
18
19
20
21
22
23
24
25
26
27
Fig. 5
Grinder system
5.1.5 Level sensor
The piezoresistive pressure sensor placed in the controller is
connected via a hose to a pressure tube in the tank. The screw
cap where the hose is connected includes a connection for a DN
100 tube. This tube, the pressure tube, extends down into the
tank. The rising liquid level compresses the air inside the
pressure tube and hose, and the piezoresistive sensor transforms
the changing pressure into an analogue signal. The control box
uses the analogue signal to start and stop the pump and to
indicate high water-level alarm. The pressure tube is fixed
underneath the screw cap and can be taken out for maintenance,
service and for cleaning the inside of the tube. An O-ring ensures
tightness.
The hose is supplied in a length of 10 m. The hose must be
connected to the controller.
Fig. 6
Screw cap with hose and DN 100 tube