BA230
C6
DECELERATIONS
C8
FINAL STROKE
C13
T3 ADDITIONAL TIME
Enables the type 1 deceleration function.
Y1
With this selection you can regulate the motors thrust.
A decrease in the leaf speed may be not noticeable.
Enables the type 2 deceleration function.
Y2
With this selection, the variation in the leaf speed is more noticeable.
Enables the type 3 deceleration function.
Y3
Mix of the 2 previous modalities.
The functioning is deeply influenced by the type of motor.
Enables the type 4 deceleration function. This modality is to be used in
case of emergency or particular functioning conditions. The motor is
Y4
driven in Y1 modality for 1s, then it turns off for 1s. The door movement
intermittent modality is synchronized with the command.
Disables the deceleration function.
N
Enables the final stroke in closing
Operation:
At the end of closing time without deceleration, a 2 s pulse with full power
is given.
Y1
If decelerations are enabled, the pulse is given at the end of the
deceleration time.
The final stroke is not managed by the safety devices.
Disabled with sliding configuration and with dead man logic.
Enables the final stroke in opening and closing
Operation:
At the end of the opening and closing time without deceleration, a 2 s
pulse with full power is given.
Y2
If decelerations are enabled, the pulse is given at the end of the
deceleration time.
The final stroke is not managed by the safety devices.
Disabled with sliding configuration and with dead man logic.
Disables the final stroke function
N
T3 excluded.
N
Sets T3 as the time set for the deceleration with the same setting of
YF
menus F1 and F5. The type of functioning is Y1.
Sets T3 as the time set for the deceleration with the same setting of
YS
menus F2 and F6. The type of functioning is Y1.
5