Ambient Temperature; Environmental Conditions - Sew Eurodrive MOVIDRIVE MDX60B Serie Instrucciones De Funcionamiento

Ocultar thumbs Ver también para MOVIDRIVE MDX60B Serie:
Tabla de contenido

Publicidad

4.4.5

Ambient temperature

The units are suitable for an ambient temperature of 40 °C, max. 60 °C with derated
output current.
To determine output current rating at higher than 40 °C, the output current should be
derated 2.5 % per °C between 40 °C and 50 °C, and 3 % per °C between 50 °C and
60 °C.
NOTA
- Use only tested units with a
output current (I
- UL certification does not apply to operation in voltage supply systems with a non-
grounded star point (IT systems).
4.4.6

Environmental Conditions

The units are for use in pollution degree 2 environments.
limited output voltage
= 8 A) as an external DC 24 V voltage source.
max
Instrucciones de funcionamiento – MOVIDRIVE
Instalación
Information regarding UL
(V
= DC 30 V) and
limited
max
®
MDX60B/61B
4
85

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Movidrive mdx61b serie

Tabla de contenido