Convection + Humidification - Combi direct - Combi Boiler
1.1B PROGRAMMING AND OPERATION
Models CD (Combi Direct) (Fig. 1B)
Convection forced hot air cycle
(temperature range between 50-270°C)
Turn the cycle selector knob (A) to the symbol shown
on the left and select the cooking temperature using
thermostat knob (B).
Combination cycle, hot air and steam
(temperature range between 50-270°C)
Turn the cycle selector knob (A) to one of the seven
adjustment positions among the symbols shown on
the left (with steam flow from a minimum to a
maximum) and select the cooking temperature using
thermostat knob (B).
The selector knob (A) allows seven steps for steam
adjustment.
Steam cycle
(temperature range between 50-100°C)
Turn the cycle selector knob (A) to the symbol
shown on the left and select the cooking
temperature using the thermostat knob (B).
ATTENTION. The max. allowed temperature will be
100°C, even if the thermostat knob will be positioned
on higher values.
Cooling down cycle
Open the door and turn the cycle selector knob (A)
to the symbol shown on the left. This cycle allows
the motor fan to work with open door, and to cool
down quickly the cooking chamber.
1.2B
COMPONENTS DESCRIPTION FOR CONTROL PANEL MOD. CD
A
Cycle selector knob
B
Cooking chamber thermostat
C
Timer
D
Chamber lighting ON/OFF button
E
Pilot light timer ON
F
Pilot light oven power supply ON
G
Pilot light cooking chamber heating ON
Z
Gas burner ignition re-set button
14
- Analogic -
Fig. 1B
Fig. 1B