Settings; User Settings; Basic Settings - Sicam SBM 55 NW Manual Original

Máquina de equilibrado de ruedas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 108
en
50 | SBM 55 NW | Settings

10. Settings

10.1

User settings

i
Settings which can be made by the user.
1. Keep the <MENU> key pressed for 3 seconds.
2. As soon as SET appears in the left-hand display, release the <MENU> key.
"
TOL appears in the left-hand display and the current value in the right-hand display.
"
To scroll press <MENU>
Function
Change of setting/value
Access to next setting, altered settings are stored
Exit from menu.
Attention: Altered setting is however stored
Setting
Tolerance for display value "0"
Display resolution
Balance weight
Unit for balance weight
Acoustic signal
Automatic start
Data arm selection
10.2

Basic settings

i
Basic settings which can only be made following consultation with or by customer service.
1. Press and hold the <MENU> key.
2. As soon as SET appears in the left-hand display, release the <MENU> key.
3. Press the <mm/inch> key within 1.5 seconds.
"
POT appears in the left-hand display and the current setting in the right-hand display.
i
This gains access to the factory setting menu, reserved to technical assistance.
"
To exit press <SPLIT>
|
1 695 656 076
2012-03-28
Left display
Right display
TOL
Current value in
grams / ounces
RES
1 or 5
UNB
GRA
OUN
SND
ON
OFF
CAR
ON
OFF
MOT
ON
OFF
Key
<-> or <+>
<OK> or <MENU>
<STOP>
Description
Entry of balance weight value below which the value "0" is to
be displayed.
Standard value 4,5 g (0,25 oz), maximum value 25 g (0,25 oz)
5 g / 0.25 oz - Standard resolution
1 g / 0.05 oz - Fine resolution
GRA =
Display in grams
OUN =
Display in ounces
ON =
An acoustic signal sounds on storing the data
determined
OFF =
No acoustic signal sounds on storing the data
determined
ON =
Start of measurement by closing wheel guard
OFF =
Start of measurement by pressing <START> key
(with wheel guard closed)
ON =
Use is made of standard data arm
OFF =
Use is made of long data arm for balancing of
motorcycle wheels
Setting not possible, always select OFF