Mounting the Sensor
2.1

Special Considerations

Ensure sensor is firmly mounted
on a flat surface. Avoid vibra-
tions.
2.2

Mounting Instructions

1. Remove sensor unit from mounting bracket by loosening handscrews.
2. Affix the self-adhesive mounting template to the wall or ceiling and drill holes in specified lo-
cations. Remove the template once the holes have been drilled.
3. Route the cable through the opening in the mounting bracket and ensure cable length is suffi-
cient to accomodate desired inclination angle.
4. Secure the mounting bracket tightly to the wall or ceiling using screws.
5. Attach sensor to mounting bracket by aligning the pins and screws on the sensor with the slots
on the mounting bracket. Ensure both sides are seated properly.Tighten handscrews to secure.
6. Connect cable to door operator (refer to door operator manual for wiring diagram).
Ideal mounting location
Center over door
x
x
2.3
Inclination Angle
After mounting, adjust the inclination angle to the desired detec-
tion pattern. Adjust the inclination angle by loosening the hand-
screws on the sides of the sensor and adjusting as shown below.
Range is 0 - 90°, in 15° increments as marked on the mounting
bracket. 30 - 45° is typical for most applications.
2.4
Tilt Angle
It may be necessary to tilt the sensor for certain applications (not recommended unless war-
ranted by special circumstances). To do so, loosen the handcrews and remove the sensor from
the bracket. Once the mounting screws are accessible, loosen them enough to twist the bracket
to change the tilt of the sensor.
2
Objects such as fans, plants,
flags, etc must not protrude into
the detection area.
Self-adhesive mounting template
28 mm
Mounting screws
Front view, 45° angle shown
166 mm
Obstruction can effect perfor-
mace of sensor. Make sure sensor
has an unobstructed view.
Extra heigth
for tilted device.
13 mm
28 mm
+
Mount sensor away from fluores-
cent or HID light sources.
Attaching the sensor to the bracket
Optional ceiling mounting
125 mm
41 mm
50 mm
min.
50mm
Example of application
requiring tilt adjustment
+