Functions & Settings - Programming Sensor with Buttons on Unit
In cases when no remote control is available, several crucial functions
can be programmed by using the buttons on the sensor unit.
All remaining functions must be configured by remote control.
1. Unscrew all front cover screws and remove the front cover to locate
buttons.
L
R
1. Briefly press
and
L
3. Press button
to change the function. The function increases by 1
for every button press. Once the last function has been reached, the
program returns to the first function. The red LED flashes to indicate
the number of the activated function.
R
4. Press button
to change the value. The value increases by 1 for
every button press. Once the last value has been reached, the program
returns to the first level.
L
R
5. Briefly press
and
or wait 25 sec and the sensor will exit automatically.
6. Replace the front cover and tighten all 4 screws.
Function
Mounting Height
Output 1 Configuration
Output 1 Field Size/
Sensitivity
Wide Field Setting
6.3
Wide Field
1. Activate the wide field setting
If wide sensing field is desired, follow programming instructions
below and use the clip accessory on the sensor unit.
The sensor will not function correctly if the clip is used
i
without the proper wide field setting or vice versa.
The wide field setting is only available for for mounting heights up
to 4 m. Sensor will not allow wide field setting to be activated if a
higher mounting height is selected.
Normal field without clip*
Value
Wide Field Setting
1
Off *
2
on
* factory setting
7
simultaneously to enter programming mode
simultaneously to exit programming mode
Green LED
Red LED
Function #
Values
(Button L /
(Button R / Green LED)
Red LED)
1
1-6 (see table on pg 5)
2
1-9 (see table on pg 5)
3
1-5 (see table on pg 5)
4
1-2 (see sec. 6.3 below)
Wide field with clip
6.1

Factory Reset

L
R
simultaneously and hold for 8 seconds.
– Press
and
– Every 2 seconds, one LED illuminates briefly.
– Both LED's illuminate after 8 seconds
– The reset is complete when both buttons are released.
6.2
Programming Addresses 1-4 (by DIP Switch on the Sensor)
Unscrew the 4 front cover screws and remove the front cover of the
sensor to locate the DIP switches (refer to section 1.3 for more in-
formation). Ensure the cover is closed securely when addressing is
complete.
L
R
Briefly press
and
simultaneously to enter
programming mode.
R
Press
once to turn on
wide field and twice to turn
off (factory setting = off).
The green LED will blink the
corresponding # of times to
verify selection
Button R
Button L
1 2
O
N
Address 1
1 2
O
Address 2
N
1 2
Address 3
O
N
1 2
O
Address 4
N
L
Press
3 times to enter
wide field function. The red
LED will blink 4 times.
L
R
Briefly press
and
simultaneously to exit
programming mode.
Changes are saved
immediately.