Commercial warranty on the instrument
The commercial warranty offered by Meta is a guarantee of good functioning
against defects arising as a result of long-term use.
The SMARTACT evo device is covered by warranty in accordance with the
law for 12 months from the date of sale stated on the invoice.
The warranty does not cover improper use of the device. Improper use in-
cludes the following: repairs and maintenance performed by persons not
authorised by the manufacturer, defects or damage caused by falling, bre-
aking, lightning strikes or liquid penetration, defects or damage caused by
mechanical, chemical or thermal effects, devices fitted with components or
accessories not authorised by the manufacturer. In order to exercise their
rights, customers must report any conformity defect within two months
from discovery of such defect. In the event of replacement of a product or
SCHEME 1 - INSTRUMENT ASSEMBLY
Insert the inertial system (G) into
the curved body (H)
Take the single-use striker (M) from
the blister pack and insert it into the
curved body (H)
Insert the curved body (H) into
place in the upper ring nut (F)
Pay the utmost attention and make sure that you have correctly engaged the thread and firmly screwed the ring nuts
into place.
8
1
Screw it fully into place using the
dedicated locking wrench provided
(J). NB: Firmly tighten into place
4
Take the single-use tack insertion
device (L) from the blister pack and
insert it into the head ring nut (I)
7
Screw the curved body with ring nut
(Photo 7) onto the upper side of the
central body of the handpiece (E)
tightening it into place.
SMARTACT
component, the products or individual components returned for replacement
become the property of the manufacturer. A service provided under warranty
does not extend the original warranty period. Therefore, in the event of repla-
cement of a product or component, the part that is supplied in replacement
of a defective part shall not be warranted longer than the expiration of the
original warranty period of the defective part. All other rights are excluded.
These instructions for use as well as further information on the instrument
and the assembly and disassembly sequences of SMARTACT evo are avai-
lable on the website www.metahosp.com
Only by reading this documentation can you avoid errors and ensure proper
functioning of our product.
2
Open the sterile SMARTACT evo
Pin blister pack containing the
single-use pins and components.
5
Screw the head ring nut into place
(with the single-use tack insertion
system as shown in Photo 5) on
the head of the curved body (H)
containing the single-use striker (M)
8
Assembled handpiece
evo
Assembling the handpiece
3
6
9
SMARTACT