English
To validate the new value press
3 times.
Important: These changes should be performed by a qualifi ed
professional installer, they should be performed in production
or on site during the fi rst installation.
6.3 Restoring factory settings (only if PIN code is disabled)
If the PIN code is disabled, the user and installer settings are reinitialized:
1- From the PIN code, press
2- no appars . Press
or
YES = Factory settings reset.
no = Factory settings not reset.
. To exit the EXpert settings, press
. rEST appears briefl y on the display.
to select YES.
3- Press the key
confi guration and goes back automatically to the home display of the
instaler settings.
The following factory values will be eff ective:
Settings
Comfort setting temperature
Boost duration
Keypad lock
User settings
Eco mode temperature lowering level
Frost protection temperature
Super Comfort
Minimum set of Comfort setting
temperature
Maximum set of Comfort setting
temperature
Maximal Boost duration
Maximum ambient temperature
for the automatic stop of the Boost
Automatic open window
detection
Occupancy detection
Dual optimization feature
PIN code protection
Expert settings
Reg. Ambient temperature sensor
PIN code
Ambient temperature sensor adj.
To exit the expert settings, press
7. Troubleshooting
Batteries are used inadapted.
- Replace the 2 batteries. Only use alkaline 1,5V LR6 batteries.
Do not use rechargeable batteries.
The heating does not come on or does not go off .
- Your remote control may have been set up close to a source of heat
or on a cold wall - put it in a recommended location (see the "Installing"
section for these locations).
- No power supply to the device: check the fuse and the circuit breaker..
The ambient temperature is lower than the required temperature
- Refer tothe device instruction manual.
Radio transmission is not working properly :
1- The device is not picking up the code sent by the emitter.
- Replace transmitter's batteries.
2- The device does not recognize transmitter's code.
- Pair the remote control transmitter with the device again.
- 40 -
for 5 seconds. The device returns to its initial
Factory settings
Operation
19°C
60 min.
Disabled
60 min.
-3,5°C
7°C
Enabled
7°C
30°C
60 min.
35°C
Enabled
Enabled
Opti Comfort
Disabled
Opti Comfort
0,0
0000
0,0
3 times.
Cod. 1910000000274 - nv01