13.4.e - Squeegee pressure adjust-
ment (Fig. O)
Depending on the type of floor to be
treated or after replacing the squee-
gee rubbers, it may be necessary to
adjust
the
squeegee
To adjust it, act as follows:
- Lift the recovery water tank (11) making
sure it is empty.
- Act on the adjustment screw (71) taking
into account that:
• Turning
clockwise
squeegee floor pressure.
• Turning counterclockwise increases
the squeegee floor pressure.
- At the end of the adjustment, carefully
lower the recovery water tank (11).
13.4.f - Cleaning the clean water
filter (Fig. P)
- Make sure that the tank (13 Fig A) is emp-
ty.
- Remove the cap (22) and take out the fil-
ter cartridge (72).
- Clean the filter cartridge (72) using run-
ning water.
- Reassemble everything proceeding in re-
verse making sure that the gasket (73) is
placed correctly.
13.4.g - Checking the wear status of
the three wheels (Fig. A)
- Check the wear status of the three wheels
(8) and (23) periodically; if they appear
worn or damaged, contact a technical
service centre in order to have them re-
placed.
DANGER:
Operating the machine with worn or
damaged wheels poses a danger to
the operator as the machine could
have less traction when turning.
floor
pressure.
decreases
the
ENGLISH - 17
14 -