parts can nullify the liability from the results of
their usage.

2.7 Improper use

The operating safety of the supplied product is
only guaranteed for conventional use in accord-
ance with Section 4 of the operating instructions.
The limit values must on no account fall under or
exceed those specified in the catalogue/data
sheet.
3 Transport and interim storage
Immediately after receiving the product:
• Check product for transport damage,
• In the event of damage in transit, take the neces-
sary steps with the forwarding agent within the
respective time limits.
CAUTION! Risk of damage!
Inappropriate transport and interim storage can
cause damage to the product.
• The switchgear is to be protected against mois-
ture and mechanical damage.
• It must not be exposed to temperatures outside
the range –20 °C to +60 °C.
5.2

Technical data

Mains supply voltage [V]:
Frequency [Hz]:
Max. rating [kW]:
Max. current [A]:
Protection class:
Max. fuse protection on mains side [A]:
Ambient temperature [°C]:
Alarm contact:
Housing material:
Housing dimensions:
Electrical safety:

5.3 Scope of delivery

• Switchgear EC-Drain LS2 (with integrated buzzer)
• Alternating current (single-phase 230 V) with
shock-proof plug
• Three-phase current (three-phase 400 V) with
CEE plug

• Installation and operating instructions

5.4 Accessories
Accessories must be ordered separately:
• Rechargeable battery (NiMH) 9 V/200 mAh
• Horn 230 V/50 Hz
• Flashing light 230 V/50 Hz
• Signal lamp 230 V/50 Hz
See the catalogue for a detailed list
Installation and operating instructions Wilo-Control EC-Drain LS2

4 Intended use

The EC-Drain LS2 switchgear is for automatic
control of two pumps with a maximum power
consumption of P
• in lifting units,
• in sewage sumps,
• for submersible pumps.
DANGER! Risk of fatal injury!
The switchgear is not protected against explo-
sions and may not be operated in the explosive
area.
Always install the switchgear outside the explo-
sive area.
The intended use includes complying with these
instructions.
Any other use is considered outside the intended
use.

5 Product information

5.1 Type key
Example:
EC
Drain
LS2
(1~)
single-phase 230 V (L, N, PE)
three-phase 400 V (L1, L2, L3, PE)
50/60 Hz
P
4 kW, AC 3
2
12 A
IP 54
16 A, slow-blow (with premounted cable 1.5 mm² and 16 A
CEE/shock-proof plug)
25 A, slow-blow (with premounted cable 4.0 mm² and 32 A CEE plug or
with direct power supply to terminal)
–20 to +60 °C
Contact load max. 250 V~, 1 A
ABS
289 mm x 239 mm x 107 mm (WxHxD)
Degree of contamination II

6 Description and function

6.1 Product description (Fig.`1)
The EC-Drain LS2 is an electronic switchgear with
an integrated microcontroller.
It controls two pumps depending on the switching
status of the connected float switch. When the
high water level is reached, optical and acoustic
signals are output and there is a forced pump
switch-on. The collective fault signal and high
water alarm are active.
An optional rechargeable battery (accessory)
allows for a mains-independent alarm signal,
which signalises the missing mains voltage by
means of a continuous acoustic signal.
= 4.0dkW:
2
EC-Drain LS2 (1~)
Economy-Controller
Wastewater/sewage
Lifting station for 2 pumps
(1~) = single-phase 230 V (L, N, PE)
(3~) = three-phase 400 V (L1, L2, L3, PE)
English
13