Fuji Electric FRENIC-Eco FRN-F1 Serie Guía Rápida página 17

Variador de frecuencia para control de bombas y ventilación
Ocultar thumbs Ver también para FRENIC-Eco FRN-F1 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E codes: Extension terminal functions
Code
Name
E01
Command assignment to:
[X1]
E02
[X2]
E03
[X3]
E04
[X4]
E05
[X5]
E20
Command assignment to:
[Y1]
E21
[Y2]
E22
[Y3]
E24
[Y5A/C]
E27
[30A/B/C]
Data setting range
Selecting function code data assigns the corresponding function to terminals [X1] to [X5] as
listed below. Setting the value of 1000s in parentheses () shown below assigns a negative logic
input to a terminal.
0 (1000): Select multistep frequency
1 (1001): Select multistep frequency
2 (1002): Select multistep frequency
6 (1006): Enable 3 -wire operation
7 (1007): Coast to stop
8 (1008): Reset alarm
9 (1009): Enable external alarm trip
11 (1011): Switch frequency command 2/1
13: Enable DC brake
15: Switch to commercial power (50 Hz)
16: Switch to commercial power (60 Hz)
17 (1017): UP (Increase output frequency)
18 (1018): DOWN (Decrease output frequency)
19 (1019): Enable write from keypad (Data changeable)
20 (1020): Cancel PID control
21 (1021): Switch normal/inverse operation
22 (1022): Interlock
24 (1024): Enable communications link via RS485 or field bus (option)
25 (1025): Universal DI
26 (1026): Select starting characteristics
30 (1030): Force to stop
33 (1033): Reset PID integral and differential components
34 (1034): Hold PID integral component
35 (1035): Select local (keypad) operation
38 (1038): Enable to run
39: Protect motor from dew condensation
40: Enable integrated sequence to switch to commercial power (50 Hz)
41: Enable integrated sequence to switch to commercial power (60 Hz)
50 (1050): Clear periodic switching time
51 (1051): Enable pump drive (motor 1)
52 (1052): Enable pump drive (motor 2)
53 (1053): Enable pump drive (motor 3)
54 (1054): Enable pump drive (motor 4)
87 (1087): Switch RUN command 2/1
88: RUN forward 2
89: RUN reverse 2
Selecting function code data assigns the corresponding function to terminals [Y1] to [Y3],
[Y5A/C], and [30A/B/C] as listed below. Setting the value of 1000s in parentheses () shown
below assigns a negative logic input to a terminal.
0 (1000): Inverter running
1 (1001): Frequency arrival signal
2 (1002): Frequency detected
3 (1003): Undervoltage detected (inverter stopped)
5 (1005): Inverter output limiting
6 (1006): Auto -restarting after momentary power failure
7 (1007): Motor overload early warning
10 (1010): Inverter ready to run
11: Switch motor drive source between commercial power and inverter
output (For MC on commercial line)
12: Switch motor drive sou rce between commercial power and inverter
output (For primary side)
13: Switch motor drive source between commercial power and inverter
output (For secondary side)
15 (1015): Select AX terminal function
25 (1025): Cooling fan in operation
26 (1026): Auto -resetting
27 (1027): Universal DO
28 (1028): Heat sink overheat early warning
30 (1030): Service life alarm
33 (1033): Command loss detected
35 (1035): Inverter output on
36 (1036): Overload prevention control
37 (1037): Current detected
42 (1042): PID alarm
43 (1043): Under PID control
44 (1044): Motor stopping due to slow flowrate under PID control
45 (1045): Low output torque detected
54 (1054): Inverter in remote operation
55 (1055): Run command activated
56 (1056): Motor overheat detected (PTC)
60 (1060): Sequenced start motor 1, inverter-driven
61 (1061): Sequenced start motor 1, commercial-power driven
Chapter 6: Function codes and application example
Default setting
6
7
8
11
(SS1)
35
(SS2)
(SS4)
(HLD)
(BX)
(RST)
(THR)
(Hz2/Hz1)
(DCBRK)
(SW50)
(SW60)
(UP)
(DOWN)
(WE-KP)
(Hz/PID)
(IVS)
(IL)
(LE)
(U-DI)
(STM)
(STOP)
(PID-RST)
(PID-HLD)
(LOC)
(RE)
(DWP)
(ISW50)
(ISW60)
(MCLR)
(MEN1)
(MEN2)
(MEN3)
(MEN4)
(FR2/FR1)
(FWD2)
(REV2)
0
1
2
10
(RUN)
99
(FAR)
(FDT)
(LU)
(IOL)
(IPF)
(OL)
(RDY)
(SW88)
(SW52-2)
(SW52-1)
(AX)
(FAN)
(TRY)
(U-DO)
(OH)
(LIFE)
(REF OFF)
(RUN2)
(OLP)
(ID)
(PID-ALM)
(PID-CTL)
(PID-STP)
(U-TL)
(RMT)
(AX2)
(THM)
(M1_I)
(M1_L)
14

Publicidad

Tabla de contenido
loading

Tabla de contenido