Descargar Imprimir esta página

Comunello Automation QUAD-24V-HP Instrucciones De Uso Y De Instalacion página 13

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

6 MENU DESCRIPTION AND PROGRAMMABLE FUNCTIONS
The control panel has a MAIN MENU and three sub-menus called EXTENDED MENUS to customize the programming and the various system
functions.
Pressing the SELECT button several times in succession you can scroll through the menu displayed by the 7 LEDs to choose the desired
function (flashing LED correspondingly flashing) and change its functionality with the SET button (the LED becomes fixed with function enabled
or, conversely, off with function disabled).
THE "LEV" LED STATUS INDICATES WHICH MENU IS ACTIVE"
Use the SELECT key by pressing it several times to select the desired function (the corresponding LED flashes) in the displayed menu and
confirm with the SET key:
The first available menu is the MAIN menu summarized in Tab no. 2:
• Press the SELECT button and select the desired function from the
MAIN MENU
main menu
LIVEL 0 - MAIN MENU
LED
FUNCTION
DESCRIPTION
L1
STEP BY STEP
Selection of the opening logic
L2
CODE TX
Storage of remote controls
L3
CONDO
Activate
the
function
L4
MOTOR TIME
Storage of the motor stroke with
slowdowns
L5
PAUSE TIME
Automatic closing setting
L6
DELAY
Adjustment of the delay between
the 2 leaves
L7
AUTO PROGRAM
Self-learning of the stroke with
slowdowns
Table 2
The second menu is the one defined as EXTENDED 1 and to access the programmable functions follow the instructions given in Tab. 3:
E X T E N D E D
• Press the SELECT button and scroll the LED menu until you reach
MENU 1
the LEV LED;
• Press SET once to access the EXTENDED menu 1.
LIVEL 1 - EXTENDED MENU 1
LED
FUNCTION
DESCRIPTION
L1
HOLD-TO-RUN
Hold-to-run input
L2
PEDESTRIAN
/
Configuration of pushbuttons inputs
SINGLE
LEAF
PP and PPED
PUSHBUTTON
L3
P E D E S T R A I N
Configuration of the PPED input
BUTTON / DS3
as partial opening or as additional
photocell input
L4
PHOTOTEST
Perform the photocell test before
each movement
L5
DS2
STOP
IN
Configuration of DS2 photocells
CLOSE
input
L6
DS1
PARTIAL
Configuration of DS1 photocells
INVERTION
input
L7
BLOCK / 8K2
Configuration of N.C. STOP or 8.2
K Ohm resistive input.
Table 3
Open-Stop-Close-Stop (it closes after the pause time in a partial opening
phase)
Memorised controls
"Condominium"
After the first one, the other inputs are ignored during the opening and the
pause time
Stored stroke
Automatic closing period stored
4 sec. in OPEN, adjustable from 4 to max. 15 sec. in CLOSE
Memorized self-learning of the stroke
Enabled function
N.O. PPED button acts like single leaf (performing the stored stroke of
MOT1)
OPEN
and
CLOSE
PP: Open
PPED: Close
Configuration of N.O. PPED input as DS3
Enabled function
STOP in CLOSE once the contact is open, then reversal
Partial reversal in CLOSE
8.2 K Ohm resistive input configuration
The LEV function LED stays on FIXED:
LED ON
Automatic (Open-Close)
Empty storage
Disabled function
30 seconds, without slowdown
(default)
Not active
Leaf delay disabled
Disabled function
The LED of the LEV function FLASHES with this frequency
LED ON
Disabled function
Partial
PP:
by
2
different
buttons:
PPED: partial open of MOT1
Configuration of the PPED input as
N.O. Pedestrian input
Disabled function
Reversal in CLOSE
Complete reversal in CLOSE
N.C. STOP pushbutton
COMUNELLO ®Copyright 2021 - All rights reserved
LED OFF
DEFAULT
LED OFF
DEFAULT
opening/pedestrain
leaf
Open
/
Close
button
41

Publicidad

loading

Productos relacionados para Comunello Automation QUAD-24V-HP