motion except in the last 5 sec. of the stroke in which it makes a stop.
- In the absence of encoders and electronic limit switches, the detection of the obstacle takes place by current measurement. To
guarantee this functionality it is necessary to adjust the slow-down trimmers as follows:
Minimum recommended settings for obstacle / limit switch
MODEL
SLOWING
80%
30%
80%
30%
SPEED
50%
20%
50%
20%
In the absence of encoder and limit switch, in the last 5 seconds of the motor time, the stop of the leaves is interpreted as the limit
switch.
7.3.6 BLACK-OUT
In case of power failure and subsequent reactivation of the mains voltage, the first maneuver will be opened with a fixed and reduced speed
compared to the trimmer SPEED ; when the presence of a mechanical blockage is encountered, in the absence of an electric limit switch,
the leaves do not go into obstacles, but execute a STOP. While sending a later input, the leaves always close at a reduced speed until they
are completely closed. The following movement will be done with the speeds defined by the trimmers.
8 DETAILED DESCRIPTION OF THE PROGRAMMING
PROGRAMMING:
SELECT key: it determines the type of function to be memorized, as indicated by the blinking of the LED.
By pressing the key several times, it is possible to scroll the menu and move to the desired function. The selection remains active for 10
seconds, displayed by the flashing LED; when this interval elapses, the control unit exits programming.
SET key: it confirms and changes the programming according to the type of function determined by the SELECT key.
Following confirmation, the respective LED remains on / off for about 2 sec. and then starts flashing again.
Important notes:
- the function of the SET key can also be replaced by the remote control if previously programmed (LED L2 CODE TX lit).
- Programming enabled only with the closure of N.C contacts enabled.
8.1 MAIN MENU
L1
STEP BY STEP
L2
CODE TX
L3
CONDO
L4
MOTOR TIME
L5
PAUSE TIME
L6
DELAY
L7
PRG AUTOM
LEV
MENÙ
8.1.1 LED L1 - STEP BY STEP or OPEN-CLOSE:
Programming
In the default configuration the control unit is set with "Step-By-Step" operating logic enabled (LED no.1 ON);
if the "Automatic Open-Close" operating logic is required (LED no.2 OFF), proceed as follows:
• By the key SELECT, position yourself on the blinking LED no.1;
• Press the SET key;
• The LED L1 turns off and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.1.2. LED L2 - CODE TX:
CODE TX: Remote controls storage
Up to 120 remotes with different codes of either the fixed or the rolling code type can be saved on the control unit
Remote control code programming of the total opening (Mot. no. 1 + Mot. no.2):
COMUNELLO ®Copyright 2021 - All rights reserved
46
30%
80%
30%
80%
30%
30%
20%
50%
20%
50%
20%
20%
Step-by-step
Remote control stored
ON
Complete stroke stored
With automatic closure
ON
ON
Automatic (Open-Close)
No remote control stored
OFF
30 s. (no slowdowns)
OFF
OFF
OFF
ON

Publicidad