In this way the control unit reduces the advancement of the gate due to inertia, corresponding to a stop or an inversion command.
Repeat the procedure if you wish to restore the previous configuration.
8.3.2 LED L2 - STEP BY STEP 1:
Proceed as follows if you wish to enable the function "Step-by-step 1":
• Make sure you have enabled the extended Menu 2 (as shown by the alternate flashing 1 1 0 1 1 0 1 1 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L2;
• Press the SET key;
• LED L2 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
Important note: the Step by Step 1 function overwrites the standard Step by Step logic and can be enabled only if the "Step-by-step" is
active and with a "Pause time" stored.
8.3.3 LED L3 - "ALWAYS CLOSE":
The control unit provides the facility to set "Always Close" operation: this function, which is programmable only if a Pause Time has already
been programmed, is activated after a power failure; if the gate open condition is confirmed a closing movement is started automatically,
preceded by 5 seconds of pre-flashing.
Important note: this function can be programmed only if a Pause Time has already been set.
If you wish to enable the function, proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.3.4. LED L4 - FOLLOW ME:
The control unit allows the "Follow me" function to be configured; programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 5 seconds after freeing the DS1 photocell, meaning the gate re-closes 5 seconds after transit of the user.
Note: this function is programmable only if a Pause Time has already been programmed.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 2 (as shown by the alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L4;
• Press the SET key;
• LED L4 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.3.5 LED L5 - PEDESTRIAN TIME
Programming of the stroke of motor no.1:
The control unit is factory set with Pedestrian opening time (associated to Motor no.1) of 10 seconds without any deceleration.
That time can be modified and decreased or increased up to 4 min. To set a new pedestrian time programming must be carried out with
the leaf associated to Motor no.1 in closed position as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L5;
• Press the SET key;
• Motor no.1 starts the opening phase;
• When the desired deceleration starting point is reached press the SET key (the leaf continues its stroke at a decelerated speed);
• The L5 LED will start to flash more slowly and the Motor will decelerate;
• When the desired position is reached, press the SET button to end the Opening cycle;
• The L5 LED will flash again normally and the motor will start Closing once more;
Repeat the procedures described above for the Closing phase.
If you do not require the control unit to perform the deceleration, during programming, when the opening and closing cycle has been
completed press the SET key twice consecutively rather than just once.
During programming, instead of the SET key on the control unit you can use the button on the remote already stored.
8.3.6. LED L6 - AUXILIARY RADIO CHANNEL OPERATING LOGIC:
The control unit allows the operating logic of the Auxiliary Radio Channel to be selected.
The control unit is factory set with "Monostable" operation of the Auxiliary Radio Channel. If you wish to enable "Bistable" operation
proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L6;
COMUNELLO ®Copyright 2021 - All rights reserved
51