Descargar Imprimir esta página

Comunello Automation QUAD-24V-HP Instrucciones De Uso Y De Instalacion página 21

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

- It is not possible to carry out Automatic Programming in the absence of limit switches and/or encoders wired to the control unit.
8.2 EXTENDED MENU 1
The control unit is factory set to allow direct selection exclusively of the main menu functions. If you wish to enable the functions described
in Extended Menu 1, proceed as follows:
• Select blinking LEV LED and press SET once;
• Press SET once
• The LED will start blinking (alternate flashing of LEV LED
In this way you have access to the setting of the following functions:
L1
HOLD-TO-RUN
L2
PEDESTRIAN BUTTON / SINGLE DOOR
PP/OPEN
PPED/CLOSE
L3
PEDESTRIAN BUTTON / DS3
L4
PHOTOTEST
L5
DS2 STOP IN CLOSE
L6
DS1 PARTIAL INVERSION
L7
BLOCK / 8K2
LEV
MENU
There will be 30 seconds to select the functions of the Extended Menu 1 using the SELECT and SET keys; once an additional 30 seconds
have elapsed the control unit reverts to the main menu.
8.2.1. LED L1 - HOLD-TO-RUN:
The
control
unit
With this function enabled using either the remotes or the Pushbuttons to operate the gate, the following operation will be obtained: the
command must be kept maintained constantly to move the gate. When the command is released, the movement will stop immediately.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 1 (as shown by the alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L1;
• Press the SET key;
• LED L1 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.2.2. LED L2 - SINGLE LEAF OR PP. BUTTON = OPEN, PED. BUTTON = CLOSE:
The control unit allows a N.O. Pushbutton to be connected (CN2 input no. 10) to activate the gate in Pedestrian Opening mode.
It is however possible to use this input to connect a N.O. pushbutton operating in a different manner.
If you wish to enable the "Single Leaf" function, proceed as follows:
• The LED will start blinking (alternate flashing 1 0 1 0 1 0 of LEV LED);
• Select blinking LEV LED and press SET once;
• Press the SET key;
• By the key SELECT, position yourself on the blinking LED L2;
With this function enabled, the Pushbutton can be used to activate exclusively Operator 1.
In contrast, if you wish to enable "OPEN-CLOSE" mode in order to use the Pedestrian Pushbutton to activate
exclusively closing of the gate and the P/P Pushbutton to (CN2 input no. 11) to activate exclusively opening of the gate,
repeat the operation described above, pressing the SELECT key twice (LED L2 will blink rapidly) instead of just once.
Repeat the procedure if you wish to restore the initial configuration.
8.2.3. LED L3 - PEDESTRIAN PUSHBUTTON / DS3:
The control unit allows a N.O. Pushbutton to be connected (CN2 input no. 10) to activate the gate in Pedestrian Opening mode.
However, this input can be used to connect a DS3 photocell:
• Select blinking LEV LED and press SET once; The LED will start blinking (alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
8.2.4. LED L4 - PHOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled.
Proceed as follows if you wish to enable the function:
ON
SINGLE LEAF
DS3
ON
ON
ON
ON
provides
the
opportunity
);
OFF
PEDESTRIAN BUTTON
PEDESTRIAN BUTTON
OFF
OFF
OFF
OFF
1 FLASH
to
set
the
"Hold-to-run"
COMUNELLO ®Copyright 2021 - All rights reserved
function.
49