The third menu is the one defined as EXTENDED 2 and to access the programmable functions follow the instructions given in Tab. 4:
E X T E N D E D
• Press the SELECT button and scroll the LED menu until you reach
MENU 2
the LEV LED;
• Press SET twice to access the EXTENDED menu 2.
LIVEL 2 - EXTENDED MENU 2
LED
FUNCTION
DESCRIPTION
L1
BRAKE
Enabling of the electronic brake
L2
STEP BY STEP 1
Step-By-Step logic
L3
ALWAYS CLOSE
Enables the sending of a CLOSE
command when the power is turned
on again
L4
FOLLOW ME
The motor automatically closes in
5 sec after passing through DS1
photocell
L5
PEDESTRIAN TIME
Storage of motor no.1 partial stroke
with slowdowns
L6
2°CH MONOSTABLE
Setting the aux. relay of the 2°CH
/
BISTABLE/TIMED
as
Bistable / Monostable /
MONO.
Temporised monostable
L7
R E M O T E L Y
Enable the remote control memory
PROGRAMMING
function without acting on the
control unit
Table 4
The fourth and last menu is defined as EXTENDED 3 and to access the programmable functions follow the instructions given in Table 5:
E X T E N D E D
• Press the SELECT button and scroll the LED menu until you reach
MENU 3
the LEV LED;
• Press SET 3 times to access the EXTENDED menu 3.
LIVEL 3 - EXTENDED MENU 3
LED
FUNCTION
DESCRIPTION
L1
SOFT STOP
Setting of gradual slowdown at the
end of the movement
L2
SOFT START
Setting of gradual slowdown at the
beginning of the movement
L3
RELEASE
STROKE
Before opening, the closing thrust is
MAX
FORCE/
activated for the electric lock release
RELEASE STROKE
L4
SLAM LOCK MAX
Activation of the push in closing for
FORCE
/
SLAM
electric lock release
LOCK
L5
ELS / CMD PED
Activation of the electric lock as
PPED input
L6
LAMP/INDICATOR
Flashing light set as pilot light or
LIGHT/COURTESY
courtesy light
LIGHT/
L7
PRELAMP / LAMP IN
Activation of the pre-flashing of 3
PAUSE
sec. before closing / Flashing during
the pause time
Table 5
Note: The control unit allows to be programmed if all the safety devices (N.C. inputs on terminals) grant a contact closed.
COMUNELLO ®Copyright 2021 - All rights reserved
42
The LED of the LEV function FLASHES with this frequency
LED ON
Enabled function
Open-Stop-Close-Stop (It DOESN'T close after the pause time in a partial
opening phase)
Enabled function
Enabled function
Partial stroke of motor no.1 stored
Bistable command
Enabled function
The LED of the LEV function FLASHES with this frequency:
LED ON
Enabled function
Enabled function
Active function
Active function
Enabled function
The courtesy light / warning light becomes an intermittent output, while the
lamp output becomes a courtesy light"
Active function: preflash in closing / Flash during pause time
LED OFF
DEFAULT
Disabled function
Disabled function
Disabled function
Disabled function
10 sec., without slowdowns
Monostable command (impulsive)
Disabled function
LED OFF
DEFAULT
Disabled function
Disabled function
Disabled function
Disabled function
Disabled function
Flashing light
Disabled function