5 – Installation
The installation, maintenance and repair of the machines must be carried out only by
qualified personnel.
The appliance must be installed so that the support surface is at least 1.20m high. The
support plane must be well leveled and dry, and stable. The machines are equipped
with height adjustable feet.
This appliance is not suitable to be installed in an area where a water jet could be used,
nor to be installed outdoors. This device is only suitable for installation in places where
its use and maintenance is restricted to qualified personnel.
To ensure correct use, the machine must be installed in places where the ambient
temperature is between + 5ºC / + 32ºC and the humidity does not exceed 70%.
It is advisable to leave a space around the machine in order to speed up maintenance
work, as well as the space for the coffee grinder.
In order to avoid the freezing of water in the machine, avoid installing it in places with
an ambient temperature equal to or lower than 0ºC. In case of freezing do not use the
machine and contact the manufacturer.
The appliance must be powered exclusively with potable and cold water in accordance
with current legislation. The pressure of the water network must be between 0.1 and
0.6 MPa. If this requirement is not met, consult the manufacturer. Between the water
network and the feeding tube of the machine, a stopcock must be installed in order to
interrupt the supply when necessary.
The water and steam expelled by the machine's tubes are extremely hot and can cause
serious injury.
Any failure to comply with the instructions and warnings given by the manufacture may
invalidate the machine's warranty.
6 – Electrical connection
The machine is supplied ready for connection according to the required specifications.
The appliance is supplied with the power cable without plug, because its fixed
installation is envisaged to the electrical network, so it is necessary to install a general
protection switch.
Before connecting the machine, make sure that the data on the rating plate correspond
to those of the electrical distribution network.
If the power cord is damaged, it must be replaced by the manufacturer, by its after-
sales service or by similar qualified personnel in order to avoid a danger.