DE
Funktion
Ölbrennerpumpe
SUNTEC
AJ 6 CC
5
SUNTEC
SUNTEC
4
2
TECHNICAL DATA
General
Mounting
Flange according to EN 225
Connection threads
Cylindrical according to ISO 228/1
Inlet and return
G 1/4
Nozzle outlet
G 1/8
Pressure gauge port
G 1/8
Vacuum gauge port
G 1/8
Valve function
Pressure regulating and cut-off*
(* except for 1002 models).
Strainer
Open area : 30 cm
Opening size : 120 x 150 m
Shaft
AJ 1000/1002 : Ø 11mm (7/16")
AJ 1003 : Ø 8 mm according to EN 225.
By-pass plug
Inserted in vacuum gauge port for 2 pipe system;
to be removed with a 4 mm Allen key
for 1 pipe system.
Weight
1,7 kg
Hydraulic data
Nozzle pressure range
C : 10 - 20 bars
E : 10 - 30 bars
Delivery pressure setting 12 bars
Operating viscosity
2 - 75 mm²/s (cSt)
Oil temperature
0 - 60°C in the pump.
Inlet pressure
2 bars max.
Return pressure
2 bars max.
Suction height
0,45 bars max. vacuum to prevent air separation
from oil.
Rated speed
3600 rpm max.
Torque (@ 45 rpm)
0,30 N.m
76
www.ecoflamburners.com
1 - Sauganschluß
3
2 - Rücklaufanschluß
3 - Manometeranschluß Öldruck
4 - Manometeranschluß Unterdruck
5 - Öldruckregulierung
6 - Zur Düse
6
Die verwendete Ölbrennerpumpe ist eine
selbstansaugende Zahnradpumpe, die als
Zweistrangpumpe über einen Entlüftungs-
filter angeschlossen werden muß. In der
Pumpe eingebaut sind Ansaugfilter und Öl-
druckregler. Vor der Inbetriebnahme sind
Manometer für Druck und Unterdruckmes-
sungen anzusetzen.
1
BITTE BEACHTEN: Vor dem Brennerstart
prüfen, dass die Rücklaufleitung offen ist.
Eine Verstopfung kann die Pumpendich-
tung beschädigen.
Capacity (L/h)
350
300
250
200
150
2
2
100
Pump capacity
5
10
15
20
25
Pressure (bars)
Viscosity = 5 cSt - rated speed = 2850 rpm
Data shown take into account a wear margin.
Do not oversize the pump when selecting the gear capacity.
IDENTIFICATION
(Not all model combinations are available
Consult your Suntec representative)
(see pump capacity curves)
A : clockwise rotation /
B : clockwise rotation /
C : anti clockwise rotation /
D : anti clockwise rotation /
AJ
6
C
Flange mounting
000 : standard model
cut-off function
002 : by-pass nozzle
no cut-off function
003 : Ø 8 mm shaft
cut-off function
Revision number
Installation
P : by-pass plug installed
AJ 6
in vacuum gauge port
for two-pipe operation
AJ 4
30
35
Oil under suction
Oil under pressure
By-passed oil
returned to tank
or to suction
Pressure
gauge port
Pressure
adjustment
By-pass
plug
inserted
Vacuum
gauge port
Return
420010259503
PUMP
AJ : basic valve
Gear set capacity
Shaft rotation
and nozzle location
(seen from shaft end)
right hand nozzle.
left hand nozzle.
left hand nozzle.
right hand nozzle.
Pressure range
C : 10-20 bars
E : 10-30 bars
C
1
000
4 P
Back
to suction
By-pass
plug
removed
ONE PIPE
Return
INSTALLATION
plugged
To nozzle
Gear set
Tenuta
albero
TWO PIPE
INSTALLATION
Inlet