1A
OPERATION
1.25 Cleaning Pump
After pumping water containing a large amount of dirt or
debris, clean out inside of pump housing.
(a)
1. Remove drain plug
any water left in pump.
2. Loosen the four knobs holding the pump cover
and remove cover.
3. Clean out dirt and debris. Inspect impeller and volute
insert for wear.
!
WARNING
The impeller may develop sharp edges. Use care
when cleaning around impeller to prevent getting cut.
1.26 Cleaning Sediment Cup
Turn fuel valve off. Remove sediment cup
(d)
. Wash them thoroughly in a nonflammable solvent.
Dry them and reinstall. Turn fuel valve on and check for
leaks.
1A-14
from pump housing and drain
(c)
and O-ring
(b)
PT3
WACKER
PT3A
1
b
a
1017SD89
d
c
1001SD13